Pith. sign in

REVIEW

Inductive sensing of magnetic microrobots under actuation by rotating magnetic fields

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2304.12144 v1 pith:YAW3FQ2D submitted 2023-04-24 physics.ins-det

classification physics.ins-det
keywords inductivemagneticmicrorobotsactuationfieldsrotatingsensingclosed-loop
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

The engineering space for magnetically manipulated biomedical microrobots is rapidly expanding. This includes synthetic, bioinspired, and biohybrid designs, some of which may eventually assume clinical roles aiding drug delivery or performing other therapeutic functions. Actuating these microrobots with rotating magnetic fields (RMFs) and the magnetic torques they exert offers the advantages of efficient mechanical energy transfer and scalable instrumentation. Nevertheless, closed-loop control still requires a complementary noninvasive imaging modality to reveal position and trajectory, such as ultrasound or x-rays, increasing complexity and posing a barrier to use. Here, we investigate the possibility of combining actuation and sensing via inductive detection of model microrobots under field magnitudes ranging from 0.5 mT to 10s of mT rotating at 1 Hz to 100 Hz. A prototype apparatus accomplishes this using adjustment mechanisms for both phase and amplitude to finely balance sense and compensation coils, suppressing the background signal of the driving RMF by 90 dB. Rather than relying on frequency decomposition to analyze signals, we show that, for rotational actuation, phase decomposition is more appropriate. We demonstrate inductive detection of a micromagnet placed in distinct viscous environments using RMFs with fixed and time-varying frequencies. Finally, we show how magnetostatic gating fields can spatially isolate inductive signals from a micromagnet actuated by an RMF, with the resolution set by the relative magnitude of the gating field and the RMF. The concepts developed here lay a foundation for future closed-loop control schemes for magnetic microrobots based on simultaneous inductive sensing and actuation.

Discussion (0). Continue with ORCID to comment.

Pith tools