In January 22, 2002, KamLAND started the data-taking. The KamLAND detector is a complicated system which consists of liquid scintillator, buffer oil, spherical balloon and so on. In order to maintain the detector safety, we constructed monitoring system which collect detector status information such as balloon weight, liquid scintillator oil level and so on. In addition, we constructed continuous Rn monitoring system for the $^7$Be solar neutrino detection. The KamLAND monitoring system consists of various network, LON, 1-Wire, and TCP/IP, and these are indispensable for continuous experimental data acquisition.