pith. sign in

arxiv: hep-ex/9911006 · v1 · submitted 1999-11-05 · ✦ hep-ex

Measurement of the trailing edge of cosmic-ray track signals from a round-tube drift chamber

classification ✦ hep-ex
keywords resolutionshapingsignalschambercosmic-rayedgeexperimentsinformation
0
0 comments X
read the original abstract

The trailing edge of tube drift-chamber signals for charged particles is expected to provide information concerning the particle passage time. This information may be useful for separating meaningful signals from overlapping garbage at high-rate experiments, such as the future LHC experiments. We carried out a cosmic-ray test using a small tube chamber in order to investigate the feasibility of this idea. We achieved a trailing-edge time resolution of 12 ns in rms by applying simple pulse shaping to eliminate a signal tail. A comparison with a Monte Carlo simulation indicates the importance of well-optimized signal shaping to achieve good resolution. The resolution may be further improved with better shaping.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.