Contribution of high energy physics techniques to the medical imaging field

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv physics/0610249 v1 pith:IKBA3U4F submitted 2006-10-27 physics.ins-det

classification physics.ins-det
keywords timingresolutionelectronicsappearsenergyenhancementfieldhigh
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

The purpose of this study was to show how advanced concepts of compact, lossless and "Time Of Flight" (TOF) capable electronics similar to those foreseen for the LHC and ILC experiments could be fairly and easily transferred to the medical imaging field through Positron Emission Tomography (PET). As a wish of explanation, the two overriding weaknesses of PET camera readout electronics, namely dead-time and timing resolution, were investigated analytically and with a Monte-Carlo simulator presently dedicated to this task. Results have shown there was room left for count rate enhancement through a huge decrease of the timing resolution well below the nanosecond. The novel electronics scheme suggested for PET in this paper has been partly inspired by the long experience led in High Energy Physics where the latter requirement is compulsory. Its structure entirely pipelined combined to a pixelation of the whole detector should allow dead-times to be suppressed, while the absence of devoted timing channel would remove the preponderant contributions to the timing resolution. To the common solution for timing would substitute an optimal filtering method witch clearly appears as a good candidate as timing resolution of a few tens of picoseconds may be achieved provided the shape of the signal is known and sufficient samples are available with enough accuracy. First investigations have yield encouraging results as a sampling frequency of 50 MHz with a 7 bits precision appears sufficient to ensure the 500ps coincidence timing resolution planed. At this point, there will be a baby step ahead to draw benefice from a TOF implementation to the design and the enormous noise variance enhancement that would come with.

Discussion (0). Continue with ORCID to comment.

Pith tools