pith. machine review for the scientific record. sign in

arxiv: 1301.3180 · v3 · submitted 2013-01-14 · ⚛️ physics.ins-det

Recognition: unknown

Operational experience, improvements, and performance of the CDF Run II silicon vertex detector

Authors on Pith no claims yet
classification ⚛️ physics.ins-det
keywords performancephysicssilicondetectordetectorsradiationsensorstevatron
0
0 comments X
read the original abstract

The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated luminosity of p-pbar collisions at sqrt(s)=1.96 TeV. Many physics analyses undertaken by CDF require heavy flavor tagging with large charged particle tracking acceptance. To realize these goals, in 2001 CDF installed eight layers of silicon microstrip detectors around its interaction region. These detectors were designed for 2--5 years of operation, radiation doses up to 2 Mrad (0.02 Gy), and were expected to be replaced in 2004. The sensors were not replaced, and the Tevatron run was extended for several years beyond its design, exposing the sensors and electronics to much higher radiation doses than anticipated. In this paper we describe the operational challenges encountered over the past 10 years of running the CDF silicon detectors, the preventive measures undertaken, and the improvements made along the way to ensure their optimal performance for collecting high quality physics data. In addition, we describe the quantities and methods used to monitor radiation damage in the sensors for optimal performance and summarize the detector performance quantities important to CDF's physics program, including vertex resolution, heavy flavor tagging, and silicon vertex trigger performance.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors

    physics.ins-det 2026-05 unverdicted novelty 4.0

    Bias voltage scans show the collected charge decreasing and depletion voltage increasing in ATLAS IBL planar pixel sensors as a function of accumulated fluence above 2e15 1 MeV-neutron equivalent per cm2, compared aga...