pith. machine review for the scientific record. sign in

arxiv: 1406.1376 · v1 · submitted 2014-06-05 · ⚛️ physics.atom-ph

Recognition: unknown

Evaluation of Long Term Performance of Continuously Running Atomic Fountains

Authors on Pith no claims yet
classification ⚛️ physics.atom-ph
keywords fountainsclockstimesensemblefountainlevelnoiseperformance
0
0 comments X
read the original abstract

An ensemble of rubidium atomic fountain clocks has been put into operation at the U.S. Naval Observatory (USNO). These fountains are used as continuous clocks in the manner of commercial cesium beams and hydrogen masers for the purpose of improved timing applications. Four fountains have been in operation for more than two years and are included in the ensemble used to generate the USNO master clock. Individual fountain performance is characterized by a white-frequency noise level below $2\times 10^{-13}$ and fractional-frequency stability routinely reaching the low $10^{-16}$s. The highest performing pair of fountains exhibits stability consistent with each fountain integrating as white frequency noise, with Allan deviation surpassing $6\times 10^{-17}$ at $10^7$~s, and with no relative drift between the fountains at the level of $7.5 \times 10^{-19}$/day. As an ensemble, the fountains generate a timescale with white-frequency noise level of $1\times 10^{-13}$ and long-term frequency stability consistent with zero drift relative to the world's primary standards at $1 \times 10^{-18}$/day. The rubidium fountains are reported to the BIPM as continuously running clocks, as opposed to secondary standards, the only cold-atom clocks so reported. Here we further characterize the performance of the individual fountains and the ensemble during the first two years in an operational environment, presenting the first look at long-term continuous behavior of fountain clocks.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Robust quantum metrology using disordered probes

    quant-ph 2026-04 unverdicted novelty 7.0

    A disorder marker derived from central moments of disorder distributions classifies quantum probes and exhibits quadratic dependence on weak identical disorder strength, enabling estimation of maximum tolerable disord...