The reviewed record of science sign in
Pith

arxiv: 2310.00657 · v2 · pith:SFD6KM35 · submitted 2023-10-01 · physics.atom-ph

High flux strontium atom source

Reviewed by Pith T0 review T1 audit T2 compute T3 formal T4 kernel pith:SFD6KM35record.jsonopen to challenge →

classification physics.atom-ph
keywords atomatomicfluxatomscapturecoldhighsensors
0
0 comments X
read the original abstract

We present a novel cold strontium atom source designed for quantum sensors. We optimized the deceleration process to capture a large velocity class of atoms emitted from an oven and achieved a compact and low-power setup capable of generating a high atomic flux. Our approach involves velocity-dependent transverse capture of atoms using a two-dimensional magneto-optical trap. To enhance the atomic flux, we employ tailored magnetic fields that minimize radial beam expansion and incorporate a cascaded Zeeman-slowing configuration utilizing two optical frequencies. The performance is comparable to that of conventional Zeeman slower sources, and the scheme is applicable to other atomic species. Our results represent a significant advancement towards the deployment of portable and, possibly, space-based cold atom sensors.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. HalluScan: A Systematic Benchmark for Detecting and Mitigating Hallucinations in Instruction-Following LLMs

    cs.CL 2026-05 unverdicted novelty 5.0

    HalluScan benchmark tests hallucination detectors on LLMs, identifies NLI Verification as top performer with 0.88 AUROC, and introduces HalluScore (r=0.41 with humans) plus a routing method for 2x cost savings.

  2. HalluScan: A Systematic Benchmark for Detecting and Mitigating Hallucinations in Instruction-Following LLMs

    cs.CL 2026-05 unverdicted novelty 4.0

    HalluScan benchmark evaluates hallucination detection in LLMs, reporting NLI Verification at AUROC 0.88 and introducing HalluScore (r=0.41 with humans) plus Adaptive Detection Routing for 2x cost savings.