Calibrator Design for the COBE Far Infrared Absolute Spectrophotometer (FIRAS)
read the original abstract
The photometric errors of the external calibrator for the FIRAS instrument on the COBE are smaller than the measurement errors on the cosmic microwave background (CMBR) spectrum (typically 0.02 MJy/sr, 1 sigma), and smaller than 0.01% of the peak brightness of the CMBR. The calibrator is a re-entrant cone, shaped like a trumpet mute, made of Eccosorb iron-loaded epoxy. It fills the entire beam of the instrument and is the source of its accuracy. Its known errors are caused by reflections, temperature gradients, and leakage through the material and around the edge. Estimates and limits are given for all known error sources. Improvements in understanding the temperature measurements of the calibrator allow an improved CMBR temperature determination of 2.725 +/- 0.002 K.
This paper has not been read by Pith yet.
Forward citations
Cited by 1 Pith paper
-
Detecting gravitational waves from cosmological phase transitions with LISA: an update
Updated LISA detection prospects for gravitational waves from phase transitions are derived from state-of-the-art sound-wave simulations, with a new web tool PTPlot provided for parameter scans.