Pith. sign in

Searching for a ringdown overtone in GW150914

9 Pith papers cite this work. Polarity classification is still indexing.

9 Pith papers citing it
abstract

We reanalyze the GW150914 post-merger data searching for quasinormal modes beyond the fundamental, quadrupolar mode. There is currently an ongoing disagreement in the literature about whether, and to what extent, the data contains evidence for a quasinormal mode overtone. We use a frequency-domain approach to ringdown data analysis that was recently proposed by the authors. Our analysis has several advantages compared to other analyses performed mainly in the time domain; in particular, the source sky position and the ringdown start time are marginalized over (as opposed to simply being fixed) as part of a Bayesian ringdown analysis. We find tentative evidence for an overtone in GW150914, but at a lower significance than reported elsewhere. Our preferred analysis, marginalizing over the uncertainty in the time of peak strain amplitude, gives a posterior on the overtone amplitude peaked away from zero at $\sim 1.8\sigma$.

citation-role summary

background 2 method 1

citation-polarity summary

fields

gr-qc 9

years

2026 6 2025 3

representative citing papers

Polarization Analysis of Ringdown Signals

gr-qc · 2026-05-14 · conditional · novelty 6.0

Constrained polarization model for Kerr ringdown modes enables inclination inference from two-detector data for non-precessing mergers but introduces biases when applied to precessing systems.

Probing higher curvature gravity via ringdown with overtones

gr-qc · 2025-12-27 · conditional · novelty 6.0

Higher-curvature terms deform the near-horizon potential of spherically symmetric black holes, producing progressively larger shifts in overtone quasinormal frequencies that remain detectable in ringdown waveforms when the fundamental mode stays close to its GR value.

Impact of sky localization uncertainty on ringdown inference

gr-qc · 2026-05-18 · conditional · novelty 5.0

Properly accounting for sky localization uncertainty in ringdown inference widens mode-amplitude posteriors, avoids bias from fixed point estimates, and leaves amplitude ratios robust for Kerr spectroscopy.

Ringdown Analysis of GW250114 with Orthonormal Modes

gr-qc · 2026-05-05 · unverdicted · novelty 5.0

Orthonormal QNM analysis of GW250114 raises the significance of the first overtone of the ℓ=m=2 mode from 82.5% to 99.9% and detects no significant deviation from Kerr predictions.

citing papers explorer

Showing 9 of 9 citing papers.