Using exact space-time pairing of 220Rn-216Po decays in PandaX-4T, the 216Po half-life is measured to be 143.7±0.5(stat)±0.2(syst) ms.
Design and Commissioning of the PandaX-4T Cryogenic Distillation System for Krypton and Radon Removal
1 Pith paper cite this work. Polarity classification is still indexing.
abstract
An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is expected to be reduced by 7 orders of magnitude with 99% xenon collection efficiency at a flow rate of 10 kg/h by design. The same system can reduce radon content in xenon by reversed operation, with an expected radon reduction factor of about 1.8 in PandaX-4T under a flow rate of 56.5 kg/h. The commissioning of this system was completed, with krypton and radon operations tested under respective working conditions. The krypton concentration of the product xenon was measured with an upper limit of 8.0 ppt.
citation-role summary
citation-polarity summary
fields
nucl-ex 1years
2025 1verdicts
CONDITIONAL 1roles
method 1polarities
use method 1representative citing papers
citing papers explorer
-
Precise Measurement of $^{216}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T
Using exact space-time pairing of 220Rn-216Po decays in PandaX-4T, the 216Po half-life is measured to be 143.7±0.5(stat)±0.2(syst) ms.