Pith. sign in

Design and Commissioning of the PandaX-4T Cryogenic Distillation System for Krypton and Radon Removal

1 Pith paper cite this work. Polarity classification is still indexing.

1 Pith paper citing it
abstract

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is expected to be reduced by 7 orders of magnitude with 99% xenon collection efficiency at a flow rate of 10 kg/h by design. The same system can reduce radon content in xenon by reversed operation, with an expected radon reduction factor of about 1.8 in PandaX-4T under a flow rate of 56.5 kg/h. The commissioning of this system was completed, with krypton and radon operations tested under respective working conditions. The krypton concentration of the product xenon was measured with an upper limit of 8.0 ppt.

citation-role summary

method 1

citation-polarity summary

fields

nucl-ex 1

years

2025 1

verdicts

CONDITIONAL 1

roles

method 1

polarities

use method 1

representative citing papers

citing papers explorer

Showing 1 of 1 citing paper.