Micro-multilayer insulation with only 10% of conventional thickness delivers higher partial discharge inception voltage and over 20 kV breakdown strength versus under 5 kV for standard insulation under 18.8 kPa low-pressure conditions.
Analysis of partial discharge characteristics of MVDC power cables optimally designed for all -electric wide body aircraft under varying pressure during takeoff and descent,
1 Pith paper cite this work. Polarity classification is still indexing.
1
Pith paper citing it
fields
eess.SY 1years
2026 1verdicts
UNVERDICTED 1representative citing papers
citing papers explorer
-
Performance Enhancement of MVDC Aircraft Cables Using Micro-Multilayer Insulation Under Low-Pressure Conditions
Micro-multilayer insulation with only 10% of conventional thickness delivers higher partial discharge inception voltage and over 20 kV breakdown strength versus under 5 kV for standard insulation under 18.8 kPa low-pressure conditions.