Recognition: unknown
Measurement on the thermal neutron capture cross section of w-180
classification
⚛️ nucl-ex
keywords
crosssectioncapturemeasuredneutronthermalw-180barn
read the original abstract
We have measured the thermal neutron capture cross section for w-180 nucleus. There is only one previous data on this cross section with a value of 30 $^{+300%}_{-100%}$ barn. To consider w-181 as a low energy neutrino source, the thermal neutron capture cross section should be measured more precisely to estimate the production rate of w-181 inside a nuclear reactor. We measured the cross section of w-180 with a natural tungsten foil and obtained a new value of 21.9 $\pm$ 2.5 barn
This paper has not been read by Pith yet.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.