A cryogenic amplifier for fast real-time detection of single-electron tunneling

classification ❄️ cond-mat.mes-hall
keywords hemtamplifierbandwidthchargecryogenicdetectionhighnoise
0
0 comments X
read the original abstract

We employ a cryogenic High Electron Mobility Transistor (HEMT) amplifier to increase the bandwidth of a charge detection setup with a quantum point contact (QPC) charge sensor. The HEMT is operating at 1K and the circuit has a bandwidth of 1 MHz. The noise contribution of the HEMT at high frequencies is only a few times higher than that of the QPC shot noise. We use this setup to monitor single-electron tunneling to and from an adjacent quantum dot and we measure fluctuations in the dot occupation as short as 400 nanoseconds, 20 times faster than in previous work.