pith. sign in

arxiv: 1009.1902 · v1 · pith:ZJ4HE7MWnew · submitted 2010-09-09 · ❄️ cond-mat.mtrl-sci

Quantitative measurement of the surface charge density

classification ❄️ cond-mat.mtrl-sci
keywords chargedensitysurfaceelectrostaticsampleallowsalterambient
0
0 comments X
read the original abstract

We present a method of measuring the charge density on dielectric surfaces. Similar to electrostatic force microscopy we record the electrostatic interaction between the probe and the sample surface, but at large tip-sample distances. For calibration we use a pyroelectric sample which allows us to alter the surface charge density by a known amount via a controlled temperature change. For proof of principle we determined the surface charge density under ambient conditions of ferroelectric lithium niobate.

This paper has not been read by Pith yet.