Comment on: "Revealing common artifacts due to ferromagnetic inclusions in highly oriented pyrolytic graphite", by M. Sepioni, R.R. Nair, I.-Ling Tsai, A.K. Geim and I.V. Grigorieva, EPL 97 (2012) 47001
pith:CMP5DO22 Add to your LaTeX paper
What is a Pith Number?\usepackage{pith}
\pithnumber{CMP5DO22}
Prints a linked pith:CMP5DO22 badge after your title and writes the identifier into PDF metadata. Compiles on arXiv with no extra files. Learn more
read the original abstract
This comment addresses several issues in the paper by Sepioni et al., where it is stated that the ferromagnetism in pristine highly oriented pyrolytic graphite (HOPG) reported by several groups in the previous years is most likely due to impurity contamination. In this comment, clear arguments are given why this statement is not justified. Furthermore, it is pointed out, that there are already measurements using element-sensitive microscopic techniques, e.g. X-ray Magnetic Circular Dichroism (XMCD) that directly proved the intrinsic origin of the ferromagnetism in graphite, also in pristine HOPG.
This paper has not been read by Pith yet.