We present an experimental approach using magnetic force microscopy for measurements of the absolute value of the magnetic penetration depth $\lambda$ in superconductors. $\lambda$ is obtained in a simple and robust way without introducing any tip modeling procedure via direct comparison of the Meissner response curves for a material of interest to those measured on a reference sample. Using a well-characterized Nb film as a reference, we determine the absolute value of $\lambda$ in a Ba(Fe$_{0.92}$Co$_{0.08}$)$_{2}$As$_{2}$ single crystal and a MgB$_2$ thin film through a comparative experiment. Our apparatus features simultaneous loading of multiple samples, and allows straightforward measurement of the absolute value of $\lambda$ in superconducting thin film or single crystal samples.