pith. machine review for the scientific record. sign in

arxiv: 1603.08483 · v2 · submitted 2016-03-28 · ⚛️ physics.ins-det · hep-ex· nucl-ex

Recognition: unknown

High voltage testing for the MAJORANA Demonstrator

Authors on Pith no claims yet
classification ⚛️ physics.ins-det hep-exnucl-ex
keywords majoranademonstratordetectorcablefeedthroughhigh-voltagehpgebeen
0
0 comments X
read the original abstract

The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge effects during the MAJORANA Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.