Pith. sign in

REVIEW 1 cited by

Versatile Super-Sensitive Metrology Using Induced Coherence

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1907.09004 v5 pith:IP3FPYNA submitted 2019-07-21 quant-ph

classification quant-ph
keywords phaseseedingsensitivitywhenbrightcaseestimationgain
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

We theoretically analyze the phase sensitivity of the Induced-Coherence (Mandel-Type) Interferometer, including the case where the sensitivity is "boosted" into the bright input regime with coherent-light seeding. We find scaling which reaches below the shot noise limit, even when seeding the spatial mode which does not interact with the sample - or when seeding the undetected mode. It is a hybrid of a linear and a non-linear (Yurke-Type) interferometer, and aside from the supersensitivity, is distinguished from other systems by "preferring" an imbalance in the gains of the two non-linearities (with the second gain being optimal at low values), and non-monotonic behavior of the sensitivity as a function of the gain of the second non-linearity. Furthermore, the setup allows use of subtracted intensity measurements, instead of direct (additive) or homodyne measurements - a significant practical advantage. Bright, super-sensitive phase estimation of an object with different light fields for interaction and detection is possible, with various potential applications, especially in cases where the sample may be sensitive to light, or is most interesting in frequency domains outside what is easily detected, or when desiring bright-light phase estimation with sensitive/delicate detectors. We use an analysis in terms of general squeezing and discover that super-sensitivity occurs only in this case - that is, the effect is not present with the spontaneous-parametric-down-conversion approximation, which many previous analyses and experiments have focused on.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Counterfactual Quantum Sensing: What Interaction-Free Measurement Can and Cannot Buy

    quant-ph 2026-07 conditional novelty 5.0 of 10

    Interaction-free interferometry carries half the Fisher information of direct probing for transmissivity, equal information per absorbed photon, and only beats direct schemes when distinguishing an object from empty s...

Pith tools