Pith. sign in

REVIEW

DIRECT-Net: a unified mutual-domain material decomposition network for quantitative dual-energy CT imaging

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2008.08331 v1 pith:L4623P4W submitted 2020-08-19 physics.med-ph eess.IV

DIRECT-Net: a unified mutual-domain material decomposition network for quantitative dual-energy CT imaging

classification physics.med-ph eess.IV
keywords dectdirect-netimageimagingmaterialnoisequantitativedecomposition
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

By acquiring two sets of tomographic measurements at distinct X-ray spectra, the dual-energy CT (DECT) enables quantitative material-specific imaging. However, the conventionally decomposed material basis images may encounter severe image noise amplification and artifacts, resulting in degraded image quality and decreased quantitative accuracy. Iterative DECT image reconstruction algorithms incorporating either the sinogram or the CT image prior information have shown potential advantages in noise and artifact suppression, but with the expense of large computational resource, prolonged reconstruction time, and tedious manual selections of algorithm parameters. To partially overcome these limitations, we develop a domain-transformation enabled end-to-end deep convolutional neural network (DIRECT-Net) to perform high quality DECT material decomposition. Specifically, the proposed DIRECT-Net has immediate accesses to mutual-domain data, and utilizes stacked convolution neural network (CNN) layers for noise reduction and material decomposition. The training data are numerically simulated based on the underlying physics of DECT imaging.The XCAT digital phantom, iodine solutions phantom, and biological specimen are used to validate the performance of DIRECT-Net. The qualitative and quantitative results demonstrate that this newly developed DIRECT-Net is promising in suppressing noise, improving image accuracy, and reducing computation time for future DECT imaging.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.