Pith. sign in

REVIEW 1 cited by

Constant TMR magnetic field sensor detectivity with bias voltage

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2103.04750 v1 pith:OUHL4CRL submitted 2021-03-08 physics.app-ph

Constant TMR magnetic field sensor detectivity with bias voltage

classification physics.app-ph
keywords noisesensitivityvoltagebiasdetectivitysensorsbehaviorfield
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

In this letter, we present a study of optimized TMR magnetic field sensors as a function of voltage bias. The 1/f low-frequency noise is quantified by the Hooge-like parameter {\alpha} which allows to compare the low-frequency behavior of various TMR sensors. The sensitivity as well as the detectivity of the sensor are characterized in the parallel state and at 0 mT. We observe that the sensitivity shows a strong voltage dependence and the noise presents an unexpected decrease, not anticipated by the Hooge's law. Moreover, surprisingly, an almost stable detectivity (140-200 nT/sqrt(Hz) at 10 Hz and 15-20 nT/sqrt(Hz) at 1 kHz) as a function of the bias voltage is observed, tending to highlight that the variation of sensitivity and noise are correlated. Even if the I-V curves are strongly non-linear and reflect the different symmetries of the conduction bands channels, the variations in sensitivity and noise seems to depend mainly on the distortion of the MgO barrier due to bias voltage. With a simple model where the normal noise and sensitivity of the TMR sensors are modified by an element having no noise and a parabolic conductance with voltage, we describe the behavior of noise and sensitivity from mV to V.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Design optimization of flux concentrators for magnetic tunnel junctions-based sensors

    cond-mat.mes-hall 2026-04 unverdicted novelty 4.0

    An analytical detectivity model derived from air-gap simulations identifies an optimal flux concentrator geometry that improves MTJ sensor performance by three orders of magnitude over a single junction.