Pith. sign in

REVIEW

A Nineteen Day Earth Tide Measurement with a MEMS Gravimeter

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2109.13715 v1 pith:M552X2I3 submitted 2021-09-28 physics.ins-det physics.app-phphysics.geo-ph

A Nineteen Day Earth Tide Measurement with a MEMS Gravimeter

classification physics.ins-det physics.app-phphysics.geo-ph
keywords memsearthgravimeterdatameasurementtimeapplicationsaveraging
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

The measurement of tiny variations in local gravity enables the observation of subterranean features. Gravimeters have historically been extremely expensive instruments, but usable gravity measurements have recently been conducted using MEMS (microelectromechanical systems) sensors. Such sensors are cheap to produce, since they rely on the same fabrication techniques used to produce mobile phone accelerometers. A significant challenge in the development of MEMS gravimeters is maintaining stability over long time periods, which is essential for long term monitoring applications. A standard way to demonstrate gravimeter stability and sensitivity is to measure the periodic elastic distortion of the Earth due to tidal forces - the Earth tides. Here we present a nineteen day measurement of the Earth tides, with a correlation coefficient to the theoretical signal of 0.979. The estimated bias instability of the proposed gravimeter is 8.18 microGal for an averaging time of ~400 s when considering the raw, uncompensated data. The bias instability extracted from the sensor electronic noise sits just under 2 mircoGal for an averaging time of ~200 s. After removing the long-term temperature and control electronics effects from the raw data, a linear drift of 268 microGal/day is observed in the data, which is among one of the best reported for a MEMS device. These results demonstrate that this MEMS gravimeter is capable of conducting long-therm time-lapse gravimetry, a functionality essential for applications such as volcanology.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.