Pith. sign in

REVIEW

High-sensitivity dual-comb and cross-comb spectroscopy across the infrared using a widely-tunable and free-running optical parametric oscillator

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2305.02908 v3 pith:TFRP7LLR submitted 2023-05-04 physics.optics

High-sensitivity dual-comb and cross-comb spectroscopy across the infrared using a widely-tunable and free-running optical parametric oscillator

classification physics.optics
keywords dual-combhighdetectionmeasurementsmid-infraredrangespectroscopybeams
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Coherent dual-comb spectroscopy (DCS) enables high-resolution measurements at high speeds without the trade-off between resolution and update rate inherent to mechanical delay scanning approaches. However, high system complexity and limited measurement sensitivity remain major challenges for DCS. Here, we address these challenges via a wavelength-tunable dual-comb optical parametric oscillator (OPO) combined with an up-conversion detection method. The OPO is tunable in the short-wave infrared (1300-1670 nm range) and mid-infrared (2700- 5000 nm range) where many molecules have strong absorption bands. Both OPO pump beams are generated in a single spatially-multiplexed laser cavity, while both signal and idler beams are generated in a single spatially-multiplexed OPO cavity. The near-common path of the combs in this new configuration enables comb-line-resolved and aliasing-free measurements in free-running operation. By limiting the instantaneous idler bandwidth to below 1 THz, we obtain a high power per comb line in the mid-infrared of up to 160 $\mu$W. With a novel intra-cavity nonlinear up-conversion scheme based on cross-comb spectroscopy, we leverage these power levels while overcoming the sensitivity limitations of direct mid-infrared detection, leading to a high signal-to-noise ratio (50.2 dB Hz$^{1/2}$) and record-level dual-comb figure of merit (3.5\times 10^8 Hz$^{1/2}$). As a proof of concept, we demonstrate the detection of methane with 2-ppm concentration over 3-m path length. Our results demonstrate a new paradigm for DCS compatible with high-sensitivity and high-resolution measurements over a wide spectral range.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.