Pith. sign in

REVIEW

An Updated Reference Frame for the Galactic Inner Parsec

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2308.03147 v1 pith:FIX3WHBR submitted 2023-08-06 astro-ph.GA astro-ph.SR

An Updated Reference Frame for the Galactic Inner Parsec

classification astro-ph.GA astro-ph.SR
keywords frameproperreferenceuncertaintiesmasersmeanmotionobservations
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

Infrared observations of stellar orbits about Sgr A* probe the mass distribution in the inner parsec of the Galaxy and provide definitive evidence for the existence of a massive black hole. However, the infrared astrometry is relative and is tied to the radio emission from Sgr A* using stellar SiO masers that coincide with infrared-bright stars. To support and improve this two-step astrometry, we present new astrometric observations of 15 stellar SiO masers within 2 pc of Sgr A*. Combined with legacy observations spanning 25.8 years, we re-analyze the relative offsets of these masers from Sgr A* and measure positions and proper motions that are significantly improved compared to the previously published reference frame. Maser positions are corrected for epoch-specific differential aberration, precession, nutation, and solar gravitational deflection. Omitting the supergiant IRS 7, the mean position uncertainties are 0.46 mas and 0.84 mas in RA and Dec., and the mean proper motion uncertainties are 0.07 mas yr$^{-1}$ and 0.12 mas yr$^{-1}$, respectively. At a distance of 8.2 kpc, these correspond to position uncertainties of 3.7 AU and 6.9 AU and proper motion uncertainties of 2.7 km s$^{-1}$ and 4.6 km s$^{-1}$. The reference frame stability, the uncertainty in the variance-weighted mean proper motion of the maser ensemble, is 8 $\mu$as yr$^{-1}$ (0.30 km s$^{-1}$) in RA and 11 $\mu$as yr$^{-1}$ (0.44 km s$^{-1}$) in Dec., which represents a 2.3-fold improvement over previous work and a new benchmark for the maser-based reference frame.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.