pith. sign in

arxiv: 2308.12105 · v2 · pith:DB3MPY7Enew · submitted 2023-08-23 · ⚛️ physics.ins-det · hep-ex

Pulse shape discrimination for the CONUS experiment in the keV and sub-keV regime

classification ⚛️ physics.ins-det hep-ex
keywords backgroundconussub-kevenergyshapevolumeallowsbulk
0
0 comments X
read the original abstract

Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are expected to interact homogeneously in the entire detector volume, specific classes of external background radiation preferably deposit their energy close to the semi-active detector surface, in which diffusion processes dominate that subsequently lead to slower rising pulses compared to the ones from the fully active bulk volume. Dedicated studies of their shape are therefore highly beneficial for the understanding and the rejection of these unwanted events. This article reports about the development of a data-driven pulse shape discrimination (PSD) method for the four 1 kg size PPC HPGe detectors of the CONUS experiment in the keV and sub-keV regime down to 210 eV$_{\text{ee}}$. The impact of the electronic noise at such low energies is carefully examined. It is shown that for an acceptance of 90% of the faster signal-like pulses from the bulk volume, approx. 50% of the surface events can be rejected at the energy threshold and that their contribution is fully suppressed above 800 eV$_{\text{ee}}$. Applied to the CONUS background data, such a PSD rejection cut allows to achieve an overall (15-25)% reduction of the total background budget. The new method allows to improve the sensitivity of future CONUS analyses and to refine the corresponding background model in the sub-keV energy region.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. New constraints on physics within and beyond the standard model from the latest CONUS datasets

    hep-ex 2026-05 conditional novelty 4.0

    New reactor antineutrino data from CONUS germanium detectors improve upper limits on neutrino magnetic moment to 5.18e-11 mu_B, millicharge to 1.76e-12 e0, NSI scale to 145 GeV, and yield sin^2 theta_W = 0.28 +0.03/-0...