Noise-reduction techniques for 1H-FID-MRSI at 14.1T: Monte-Carlo validation & in vivo application

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2309.11204 v2 pith:JYP22IMU submitted 2023-09-20 physics.med-ph

Noise-reduction techniques for 1H-FID-MRSI at 14.1T: Monte-Carlo validation & in vivo application

classification physics.med-ph
keywords vivomethodsweredatasetsdenoisingincreasedmetabolitemonte-carlo
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

Proton magnetic resonance spectroscopic imaging (1H-MRSI) is a powerful tool that enables the multidimensional non-invasive mapping of the neurochemical profile at high-resolution over the entire brain. The constant demand for higher spatial resolution in 1H-MRSI led to increased interest in post-processing-based denoising methods aimed at reducing noise variance. The aim of the present study was to implement two noise-reduction techniques, the Marchenko-Pastur principal component analysis (MP-PCA) based denoising and the low-rank total generalized variation (LR-TGV) reconstruction, and to test their potential and impact on preclinical 14.1T fast in vivo 1H-FID-MRSI datasets. Since there is no known ground truth for in vivo metabolite maps, additional evaluations of the performance of both noise-reduction strategies were conducted using Monte-Carlo simulations. Results showed that both denoising techniques increased the apparent signal-to-noise ratio SNR while preserving noise properties in each spectrum for both in vivo and Monte-Carlo datasets. Relative metabolite concentrations were not significantly altered by either methods and brain regional differences were preserved in both synthetic and in vivo datasets. Increased precision of metabolite estimates was observed for the two methods, with inconsistencies noted on lower concentrated metabolites. Our study provided a framework on how to evaluate the performance of MP-PCA and LR-TGV methods for preclinical 1H-FID MRSI data at 14.1T. While gains in apparent SNR and precision were observed, concentration estimations ought to be treated with care especially for low-concentrated metabolites.