A Unified Deep Learning Framework for Motion Correction in Medical Imaging
Pith reviewed 2026-05-23 20:34 UTC · model grok-4.3
The pith
UniMo corrects motion in medical images from multiple modalities after training once on fetal MRI.
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
Core claim
UniMo trains once on fetal magnetic resonance images and then, without any retraining, corrects motion in lung CT, brain MRI from BraTS, and other datasets from MedMNIST. The framework alternates between an equivariant neural network that removes global rigid motion and an encoder-decoder that removes local deformations, guided by a unified loss. A geometric deformation augmenter improves global correction by simulating local effects during training and supplies augmented examples. Hybrid use of image intensities and shapes produces stable performance when appearance changes across modalities.
What carries the argument
Alternating optimization of an integrated equivariant network for rigid motion and encoder-decoder for local deformations, driven by a geometric deformation augmenter and hybrid intensity-shape loss.
If this is right
- The same trained weights achieve higher accuracy than prior motion-correction methods on the tested unseen datasets.
- One training run on fetal MRI suffices for stable inference on lung CT and brain MRI without fine-tuning.
- The model handles mixtures of bulk rigid motion and local deformations in a single forward pass.
- Hybrid intensity and shape features support robustness when image contrast varies across scanners.
Where Pith is reading between the lines
- Hospitals could reduce the number of separate motion-correction models they maintain if the cross-modality claim generalizes further.
- The geometric augmenter may be the main driver of stability; an ablation that removes it would test whether the hybrid loss alone is sufficient.
- Real-time clinical streams with continuous motion could serve as a natural next test case for the same fixed weights.
Load-bearing premise
The specific combination of equivariant network, encoder-decoder, geometric augmenter, and intensity-shape features produces reliable cross-modality generalization without retraining.
What would settle it
Apply the trained UniMo model to a new imaging modality or motion range that differs markedly in appearance statistics and measure whether registration accuracy drops below the level of modality-specific baselines.
Figures
read the original abstract
Deep learning has shown significant value in medical image registration for motion correction, however, current techniques are either limited by the type and range of motion they can handle, or require iterative inference and/or retraining for new imaging data. To address these limitations, we introduce UniMo, a Unified Motion Correction framework that leverages deep neural networks to correct for various types of motion in medical imaging. UniMo exploits an alternating optimization scheme for a unified loss function to train an integrated model of 1) an equivariant neural network for global rigid motion correction and 2) an encoder-decoder network to correct local deformations. It features a geometric deformation augmenter that 1) enhances the robustness of global motion correction by addressing any local deformations, and 2) generates augmented data to improve the training process. UniMo is a hybrid model that uses both image intensities and shapes to achieve robust performance amid image appearance variations, and, therefore, it generalizes well to various medical imaging modalities without a need for network retraining. We trained and tested UniMo to track motion in fetal magnetic resonance imaging. Then we tested the trained model, without retraining, on various image modalities from three public datasets, including MedMNIST, lung CT, and BraTS. The results show that UniMo surpassed existing motion correction methods in terms of accuracy, and, notably, it enabled one-time training on a single modality while maintaining high stability and adaptability for inference across multiple unseen imaging datasets. By offering a unified solution, UniMo marks a significant advantage in challenging applications with a mixture of bulk motion and local deformations. https://github.com/IntelligentImaging/UNIMO
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript introduces UniMo, a unified deep learning framework for motion correction in medical imaging. It integrates an equivariant neural network for global rigid motion correction with an encoder-decoder network for local deformations, trained via alternating optimization on a unified loss with a geometric deformation augmenter and hybrid intensity-shape features. The model is trained on fetal MRI and tested without retraining on MedMNIST, lung CT, and BraTS datasets, with the central claim that it achieves superior accuracy and cross-modality generalization.
Significance. If the cross-modality generalization claim is substantiated with quantitative evidence, UniMo would offer a notable advance by enabling single-modality training for robust inference across diverse imaging types, addressing limitations of modality-specific or iterative methods in medical registration.
major comments (2)
- [Abstract] Abstract: The assertion that UniMo 'surpassed existing motion correction methods in terms of accuracy' and 'enabled one-time training on a single modality while maintaining high stability and adaptability for inference across multiple unseen imaging datasets' is load-bearing for the central claim yet is unsupported by any quantitative metrics (e.g., registration errors, Dice scores, error bars, or dataset sizes) or ablation results on the test modalities.
- [Methods] Methods (description of framework): The alternating optimization scheme and unified loss function are presented without explicit equations defining the loss terms, the integration of equivariant and encoder-decoder components, or how the hybrid intensity-shape features are extracted and combined; this prevents verification of whether the claimed modality-agnostic behavior follows from the architecture or requires unstated preprocessing.
minor comments (1)
- The GitHub link is provided but the manuscript does not specify which code components (e.g., augmenter implementation or training scripts) are released or how to reproduce the fetal MRI training and cross-dataset testing.
Simulated Author's Rebuttal
We thank the referee for the detailed and constructive feedback. We address each major comment below, agreeing that the abstract and methods sections can be strengthened with additional quantitative details and explicit formulations. We propose revisions accordingly.
read point-by-point responses
-
Referee: [Abstract] Abstract: The assertion that UniMo 'surpassed existing motion correction methods in terms of accuracy' and 'enabled one-time training on a single modality while maintaining high stability and adaptability for inference across multiple unseen imaging datasets' is load-bearing for the central claim yet is unsupported by any quantitative metrics (e.g., registration errors, Dice scores, error bars, or dataset sizes) or ablation results on the test modalities.
Authors: We agree that the abstract would benefit from explicit quantitative support for these claims. In the revised version, we will incorporate key metrics from our experiments, including registration errors, Dice scores with error bars, and dataset sizes for the fetal MRI training and the MedMNIST, lung CT, and BraTS test sets. This will directly substantiate the accuracy and cross-modality generalization results. revision: yes
-
Referee: [Methods] Methods (description of framework): The alternating optimization scheme and unified loss function are presented without explicit equations defining the loss terms, the integration of equivariant and encoder-decoder components, or how the hybrid intensity-shape features are extracted and combined; this prevents verification of whether the claimed modality-agnostic behavior follows from the architecture or requires unstated preprocessing.
Authors: We acknowledge that explicit mathematical definitions would improve verifiability. We will add the equations for the unified loss function, the alternating optimization procedure, the integration between the equivariant network and encoder-decoder, and the extraction/combination of hybrid intensity-shape features. These additions will clarify how the architecture supports modality-agnostic behavior without relying on unstated preprocessing steps. revision: yes
Circularity Check
No circularity in derivation chain; empirical framework with external validation
full rationale
The paper presents UniMo as an integrated DL architecture (equivariant network + encoder-decoder + geometric augmenter) trained once on fetal MRI and evaluated zero-shot on MedMNIST, lung CT, and BraTS. No equations, loss functions, or self-citations are shown that reduce any claimed prediction or generalization result to fitted parameters or prior author work by construction. The central claim is an empirical statement about cross-modality performance on public datasets, which is externally falsifiable and does not rely on self-definitional steps or imported uniqueness theorems.
Axiom & Free-Parameter Ledger
axioms (1)
- domain assumption Alternating optimization of a unified loss can jointly train rigid and deformable correction networks.
invented entities (1)
-
UniMo framework
no independent evidence
Reference graph
Works this paper leans on
-
[1]
Motion artifacts in mri: A complex problem with many partial solutions,
M. Zaitsev, J. Maclaren, and M. Herbst, “Motion artifacts in mri: A complex problem with many partial solutions,” Journal of Magnetic Resonance Imaging, vol. 42, no. 4, pp. 887–901, 2015
work page 2015
-
[2]
Prospective motion correction in brain imaging: a review,
J. Maclaren, M. Herbst, O. Speck, and M. Zaitsev, “Prospective motion correction in brain imaging: a review,” Magnetic resonance in medicine, vol. 69, no. 3, pp. 621–636, 2013
work page 2013
-
[3]
Motion-compensation techniques in neonatal and fetal mr imaging,
C. Malamateniou et al. , “Motion-compensation techniques in neonatal and fetal mr imaging,” American Journal of Neuroradiology , vol. 34, no. 6, pp. 1124–1136, 2013
work page 2013
-
[4]
Motion estimation and correction in spect, pet and ct,
A. Z. Kyme and R. R. Fulton, “Motion estimation and correction in spect, pet and ct,” Physics in Medicine & Biology , vol. 66, no. 18, p. 18TR02, 2021
work page 2021
-
[5]
J. M. Fitzpatrick, D. L. Hill, C. R. Maurer et al., “Image registration,” Handbook of medical imaging , vol. 2, pp. 447–513, 2000
work page 2000
-
[6]
Promo: real-time prospective motion correction in mri using image-based tracking,
N. White et al. , “Promo: real-time prospective motion correction in mri using image-based tracking,” Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine, vol. 63, no. 1, pp. 91–105, 2010
work page 2010
-
[7]
Slice-to-volume medical image registra- tion: A survey,
E. Ferrante and N. Paragios, “Slice-to-volume medical image registra- tion: A survey,” Medical image analysis , vol. 39, pp. 101–123, 2017
work page 2017
-
[8]
Biomedical image registration,
A. Gholipour and N. Kehtarnavaz, “Biomedical image registration,” Encyclopedia of Image Processing , pp. 24–39, 2019
work page 2019
-
[9]
Slimm: Slice lo- calization integrated mri monitoring,
Y . Sui, O. Afacan, A. Gholipour, and S. K. Warfield, “Slimm: Slice lo- calization integrated mri monitoring,” NeuroImage, vol. 223, p. 117280, 2020
work page 2020
-
[10]
Real-time fetal brain tracking for functional fetal mri,
S. Neves Silva et al., “Real-time fetal brain tracking for functional fetal mri,” Magnetic resonance in medicine , vol. 90, no. 6, pp. 2306–2320, 2023
work page 2023
-
[11]
Deep learning for retrospective motion correction in mri: a comprehensive review,
V . Spieker et al., “Deep learning for retrospective motion correction in mri: a comprehensive review,” IEEE Transactions on Medical Imaging , 2023
work page 2023
-
[12]
Real-time deep pose estimation with geodesic loss for image-to-template rigid registration,
S. S. M. Salehi, S. Khan, D. Erdogmus, and A. Gholipour, “Real-time deep pose estimation with geodesic loss for image-to-template rigid registration,” IEEE transactions on medical imaging , vol. 38, no. 2, pp. 470–481, 2018
work page 2018
-
[13]
Keymorph: Robust multi-modal affine registration via unsupervised keypoint de- tection,
M. Y . Evan, A. Q. Wang, A. V . Dalca, and M. R. Sabuncu, “Keymorph: Robust multi-modal affine registration via unsupervised keypoint de- tection,” in International Conference on Medical Imaging with Deep Learning. PMLR, 2022, pp. 1482–1503
work page 2022
-
[14]
Spaer: Learning spatio-temporal equivariant representations for fetal brain motion tracking,
J. Wang, R. Faghihpirayesh, P. Golland, and A. Ghoulipour, “Spaer: Learning spatio-temporal equivariant representations for fetal brain motion tracking,” arXiv preprint arXiv:2407.20198 , 2024. 9 Source Target UniMo Equivariant Filter KeyMorph DeepPose Source Target UniMo Equivariant Filter KeyMorph DeepPose BrainsLung CTfMRIMedMN Source Target UniMo Equi...
-
[15]
J. Wang, R. Faghihpirayesh, D. Erdogmus, and A. Gholipour, “Joint motion estimation with geometric deformation correction for fetal echo planar images via deep learning,” in Medical Imaging with Deep Learning, 2024
work page 2024
-
[16]
Equivariant filters for efficient tracking in 3d imaging,
D. Moyer, E. Abaci Turk, P. E. Grant, W. M. Wells, and P. Golland, “Equivariant filters for efficient tracking in 3d imaging,” in Medical Im- age Computing and Computer Assisted Intervention–MICCAI 2021: 24th International Conference, Strasbourg, France, September 27–October 1, 2021, Proceedings, Part IV 24 . Springer, 2021, pp. 193–202
work page 2021
-
[17]
Svort: iterative transformer for slice-to-volume registration in fetal brain mri,
J. Xu, D. Moyer, P. E. Grant, P. Golland, J. E. Iglesias, and E. Adalsteins- son, “Svort: iterative transformer for slice-to-volume registration in fetal brain mri,” in International Conference on Medical Image Computing and Computer-Assisted Intervention . Springer, 2022, pp. 3–13
work page 2022
-
[18]
M. W. Haskell et al. , “Network accelerated motion estimation and reduction (namer): convolutional neural network guided retrospective motion correction using a separable motion model,” Magnetic resonance in medicine, vol. 82, no. 4, pp. 1452–1461, 2019
work page 2019
-
[19]
A deep cascade of convolutional neural networks for dynamic mr image reconstruction,
J. Schlemper, J. Caballero, J. V . Hajnal, A. N. Price, and D. Rueckert, “A deep cascade of convolutional neural networks for dynamic mr image reconstruction,” IEEE transactions on Medical Imaging , vol. 37, no. 2, pp. 491–503, 2017
work page 2017
-
[20]
Deep predictive motion tracking in magnetic resonance imaging: application to fetal imaging,
A. Singh, S. S. M. Salehi, and A. Gholipour, “Deep predictive motion tracking in magnetic resonance imaging: application to fetal imaging,” IEEE transactions on medical imaging , vol. 39, no. 11, pp. 3523–3534, 2020
work page 2020
-
[21]
Cine cardiac mri motion artifact reduction using a recurrent neural network,
Q. Lyu et al. , “Cine cardiac mri motion artifact reduction using a recurrent neural network,” IEEE Transactions on Medical Imaging , vol. 40, no. 8, pp. 2170–2181, 2021
work page 2021
-
[22]
Nesvor: implicit neural representation for slice-to-volume reconstruction in mri,
J. Xu et al., “Nesvor: implicit neural representation for slice-to-volume reconstruction in mri,” IEEE transactions on medical imaging , vol. 42, no. 6, pp. 1707–1719, 2023
work page 2023
-
[23]
Retrospective motion correction of mr images using prior-assisted deep learning,
S. Chatterjee, A. Sciarra, M. D ¨unnwald, S. Oeltze-Jafra, A. N ¨urnberger, and O. Speck, “Retrospective motion correction of mr images using prior-assisted deep learning,” arXiv preprint arXiv:2011.14134 , 2020
-
[24]
M. A. Al-Masni, S. Lee, A. K. Al-Shamiri, S.-M. Gho, Y . H. Choi, and D.-H. Kim, “A knowledge interaction learning for multi-echo mri motion artifact correction towards better enhancement of swi,” Computers in biology and medicine , vol. 153, p. 106553, 2023
work page 2023
-
[25]
Autofocusing+: noise-resilient motion correction in magnetic resonance imaging,
E. Kuzmina, A. Razumov, O. Y . Rogov, E. Adalsteinsson, J. White, and D. V . Dylov, “Autofocusing+: noise-resilient motion correction in magnetic resonance imaging,” in International Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2022, pp. 365–375
work page 2022
-
[26]
J. Hossbach et al. , “Deep learning-based motion quantification from k-space for fast model-based magnetic resonance imaging motion cor- rection,” Medical physics, vol. 50, no. 4, pp. 2148–2161, 2023
work page 2023
-
[27]
Physics-informed deep learning for motion-corrected reconstruction of quantitative brain mri,
H. Eichhorn et al., “Physics-informed deep learning for motion-corrected reconstruction of quantitative brain mri,” in MICCAI, 2024
work page 2024
-
[28]
Joint frequency and image space learning for mri reconstruction and analysis,
N. M. Singh, J. E. Iglesias, E. Adalsteinsson, A. V . Dalca, and P. Gol- land, “Joint frequency and image space learning for mri reconstruction and analysis,” The journal of machine learning for biomedical imaging , vol. 2022, 2022
work page 2022
-
[29]
Motion artifact reduction for magnetic resonance imaging with deep learning and k-space analysis,
L. Cui et al., “Motion artifact reduction for magnetic resonance imaging with deep learning and k-space analysis,” PloS one , vol. 18, no. 1, p. e0278668, 2023
work page 2023
-
[30]
Exploiting motion for deep learning reconstruction of extremely- undersampled dynamic mri,
G. Seegoolam, J. Schlemper, C. Qin, A. Price, J. Hajnal, and D. Rueck- ert, “Exploiting motion for deep learning reconstruction of extremely- undersampled dynamic mri,” in International Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2019, pp. 704–712
work page 2019
-
[31]
H. Qi et al., “End-to-end deep learning nonrigid motion-corrected recon- struction for highly accelerated free-breathing coronary mra,” Magnetic Resonance in Medicine , vol. 86, no. 4, pp. 1983–1996, 2021
work page 1983
-
[32]
Neural implicit k-space for binning-free non-cartesian cardiac mr imaging,
W. Huang, H. B. Li, J. Pan, G. Cruz, D. Rueckert, and K. Hammernik, “Neural implicit k-space for binning-free non-cartesian cardiac mr imaging,” in International Conference on Information Processing in Medical Imaging. Springer, 2023, pp. 548–560
work page 2023
-
[33]
V . Spieker et al. , “Iconik: Generating respiratory-resolved abdominal mr reconstructions using neural implicit representations in k-space,” in MICCAI. Springer, 2023, pp. 183–192
work page 2023
-
[34]
Two-stage motion correction for super-resolution ultra- sound imaging in human lower limb,
S. Harput et al., “Two-stage motion correction for super-resolution ultra- sound imaging in human lower limb,” IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 65, no. 5, pp. 803–814, 2018
work page 2018
-
[35]
3d freehand ultrasound without external tracking using deep learning,
R. Prevost et al., “3d freehand ultrasound without external tracking using deep learning,” Medical image analysis , vol. 48, pp. 187–202, 2018
work page 2018
-
[36]
Automatic inter-frame patient motion correction for dynamic cardiac pet using deep learning,
L. Shi et al. , “Automatic inter-frame patient motion correction for dynamic cardiac pet using deep learning,” IEEE transactions on medical imaging, vol. 40, no. 12, pp. 3293–3304, 2021
work page 2021
-
[37]
Deep learning based joint pet image reconstruction and motion estimation,
T. Li, M. Zhang, W. Qi, E. Asma, and J. Qi, “Deep learning based joint pet image reconstruction and motion estimation,” IEEE transactions on medical imaging, vol. 41, no. 5, pp. 1230–1241, 2021
work page 2021
-
[38]
Se (3)-equivariant and noise-invariant 3d motion tracking in medical images,
B. Billot et al. , “Se (3)-equivariant and noise-invariant 3d motion tracking in medical images,” arXiv preprint arXiv:2312.13534 , 2023
-
[39]
Computing large deformation metric mappings via geodesic flows of diffeomorphisms,
M. F. Beg, M. I. Miller, A. Trouv ´e, and L. Younes, “Computing large deformation metric mappings via geodesic flows of diffeomorphisms,” International journal of computer vision , vol. 61, pp. 139–157, 2005
work page 2005
-
[40]
B. B. Avants, C. L. Epstein, M. Grossman, and J. C. Gee, “Symmetric diffeomorphic image registration with cross-correlation: evaluating auto- mated labeling of elderly and neurodegenerative brain,” Medical image analysis, vol. 12, no. 1, pp. 26–41, 2008
work page 2008
-
[41]
Multi-modal volume registration by maximization of mutual informa- tion,
W. M. Wells III, P. Viola, H. Atsumi, S. Nakajima, and R. Kikinis, “Multi-modal volume registration by maximization of mutual informa- tion,” Medical image analysis , vol. 1, no. 1, pp. 35–51, 1996
work page 1996
-
[42]
Meta- morph: Learning metamorphic image transformation with appearance changes,
J. Wang, J. Xing, J. Druzgal, W. M. Wells III, and M. Zhang, “Meta- morph: Learning metamorphic image transformation with appearance changes,” in International Conference on Information Processing in Medical Imaging. Springer, 2023, pp. 576–587
work page 2023
-
[43]
V . I. Arnol’d, “Sur la g ´eom´etrie diff ´erentielle des groupes de Lie de dimension infinie et ses applications `a l’hydrodynamique des fluides parfaits,” Ann. Inst. Fourier, vol. 16, pp. 319–361, 1966
work page 1966
-
[44]
Geodesic shooting for compu- tational anatomy,
M. I. Miller, A. Trouv ´e, and L. Younes, “Geodesic shooting for compu- tational anatomy,” Journal of mathematical imaging and vision , vol. 24, no. 2, pp. 209–228, 2006
work page 2006
-
[45]
Fast diffeomorphic image registration via fourier-approximated lie algebras,
M. Zhang and P. T. Fletcher, “Fast diffeomorphic image registration via fourier-approximated lie algebras,” International Journal of Computer Vision, vol. 127, no. 1, pp. 61–73, 2019
work page 2019
-
[46]
3d shape descriptor based on 3d fourier transform,
D. Vranic and D. Saupe, “3d shape descriptor based on 3d fourier transform,” 2001
work page 2001
-
[47]
Invariant image recognition by zernike moments,
A. Khotanzad and Y . H. Hong, “Invariant image recognition by zernike moments,” IEEE Transactions on pattern analysis and machine intelli- gence, vol. 12, no. 5, pp. 489–497, 1990
work page 1990
-
[48]
Slerpface: Face template protection via spherical linear interpolation,
Z. Zhong et al., “Slerpface: Face template protection via spherical linear interpolation,” arXiv preprint arXiv:2407.03043 , 2024
-
[49]
Spherical linear interpolation and text-anchoring for zero-shot composed image retrieval,
Y . K. Jang, D. Huynh, A. Shah, W.-K. Chen, and S.-N. Lim, “Spherical linear interpolation and text-anchoring for zero-shot composed image retrieval,” arXiv preprint arXiv:2405.00571 , 2024
-
[50]
Quatse: Spherical linear interpolation of quaternion for knowledge graph embeddings,
J. Li, X. Su, X. Ma, and G. Gao, “Quatse: Spherical linear interpolation of quaternion for knowledge graph embeddings,” in CCF International Conference on Natural Language Processing and Chinese Computing . Springer, 2022, pp. 209–220
work page 2022
-
[51]
V oxelmorph: a learning framework for deformable medical image registration,
G. Balakrishnan, A. Zhao, M. R. Sabuncu, J. Guttag, and A. V . Dalca, “V oxelmorph: a learning framework for deformable medical image registration,” IEEE transactions on medical imaging , vol. 38, no. 8, pp. 1788–1800, 2019
work page 2019
-
[52]
Transmorph: Transformer for unsupervised medical image registration,
J. Chen, E. C. Frey, Y . He, W. P. Segars, Y . Li, and Y . Du, “Transmorph: Transformer for unsupervised medical image registration,” Medical image analysis, vol. 82, p. 102615, 2022
work page 2022
-
[53]
Diffusemorph: Unsupervised deformable image registration using diffusion model,
B. Kim, I. Han, and J. C. Ye, “Diffusemorph: Unsupervised deformable image registration using diffusion model,” in European conference on computer vision. Springer, 2022, pp. 347–364
work page 2022
- [54]
-
[55]
Fetal- bet: Brain extraction tool for fetal mri,
R. Faghihpirayesh, D. Karimi, D. Erdo ˘gmus ¸, and A. Gholipour, “Fetal- bet: Brain extraction tool for fetal mri,” IEEE Open Journal of Engi- neering in Medicine and Biology , 2024
work page 2024
-
[56]
Autosegmentation for thoracic radiation treatment planning: a grand challenge at aapm 2017,
J. Yang et al. , “Autosegmentation for thoracic radiation treatment planning: a grand challenge at aapm 2017,” Medical physics , vol. 45, no. 10, pp. 4568–4581, 2018
work page 2017
-
[57]
Medmnist classification decathlon: A lightweight automl benchmark for medical image analysis,
J. Yang, R. Shi, and B. Ni, “Medmnist classification decathlon: A lightweight automl benchmark for medical image analysis,” in 2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI) . IEEE, 2021, pp. 191–195
work page 2021
-
[58]
Medmnist v2-a large-scale lightweight benchmark for 2d and 3d biomedical image classification,
J. Yang et al., “Medmnist v2-a large-scale lightweight benchmark for 2d and 3d biomedical image classification,” Scientific Data, vol. 10, no. 1, p. 41, 2023
work page 2023
-
[59]
U. Baid et al. , “The rsna-asnr-miccai brats 2021 benchmark on brain tumor segmentation and radiogenomic classification,” arXiv preprint arXiv:2107.02314, 2021
work page internal anchor Pith review Pith/arXiv arXiv 2021
-
[60]
The multimodal brain tumor image segmentation benchmark (brats),
B. H. Menze et al. , “The multimodal brain tumor image segmentation benchmark (brats),” IEEE transactions on medical imaging , vol. 34, no. 10, pp. 1993–2024, 2014
work page 1993
discussion (0)