pith. sign in

arxiv: 2410.07914 · v2 · pith:PICJ5CO4new · submitted 2024-10-10 · ⚛️ physics.ins-det · nucl-ex

Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment

classification ⚛️ physics.ins-det nucl-ex
keywords fieldn2edmcoilexperimentgeneratehighlyinsidemagnetic
0
0 comments X
read the original abstract

We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The apparatus is able to generate a 1 $\mu$ T vertical field with a relative root mean square deviation $\sigma$ ($B_z$)/$B_z$ = 3 $\times$ $10^{-5}$ over the volume of interest, a cylinder of radius 40 cm and height 30 cm. This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than 1 $\times$ $10^{-27}$ ecm.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.