Pith. Sign in

RECORD

A direct Measurement of the W Boson Width in ppbar Collisions at sqrt(s) = 1.96 TeV

High Energy Physics - Experiment · Submitted 22 Oct 2007

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The result is G_W = 2032 +/- 45 (stat.) +/- 57 (syst.) MeV, consistent with the standard model expectation.

how it is stated · asserted 0.82 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID0710.4112 (version 3)
Pith IDDYKWNOGU, Pith's permanent record of this paper and its review
CitationCDF Collaboration: T. Aaltonen, et al. "A direct Measurement of the W Boson Width in ppbar Collisions at sqrt(s) = 1.96 TeV." arXiv:0710.4112 (2007). https://pith.science/paper/DYKWNOGU
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 3,210 input tokens, $0.0001 reported.

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.12 · human participants 0.02 · controlled comparison 0.07 · randomized assignment 0.01 · states quantitative result 0.99 · compares with prior results 0.51 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v3. Results and the main claim are underlined; .

A direct measurement of the total decay width of the W boson G_W is presented using 350 pb-1 of data from ppbar collisions at sqrt(s) = 1.96 TeV collected with the CDF II detector at the Fermilab Tevatron. The width is determined by normalizing predicted signal and background distributions to 230185 W candidates decaying to enu and munu in the transverse-mass region 50 < M_T < 90 GeV and then fitting the predicted shape to 6055 events in the high-M_T region, 90 < M_T < 200 GeV. The result is G_W = 2032 +/- 45 (stat.) +/- 57 (syst.) MeV, consistent with the standard model expectation.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 A direct measurement of the total decay width of the W boson G_W is presented using 350 pb-1 of data from ppbar collisions at sqrt(s) = 1.96 TeV collected with the CDF II detector at the Fermilab Tevatron. contribution 0.94 0.96 0.08 asserted 1.00
s1 The width is determined by normalizing predicted signal and background distributions to 230185 W candidates decaying to enu and munu in the transverse-mass region 50 < M_T < 90 GeV and then fitting the predicted shape to 6055 events in the high-M_T region, 90 < M_T < 200 GeV. method 1.00 0.95 0.03 asserted 1.00
s2 The result is G_W = 2032 +/- 45 (stat.) +/- 57 (syst.) MeV, consistent with the standard model expectation. result 1.00 0.97 0.96 asserted 0.82

What kind of paper the classifier reports this is: empirical study 1.00 · evidence from observation or experiment 0.89.

What was examined, and what was not

sources read
  • arXiv listing abstract v3
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

A direct measurement of the total decay width of the W boson G_W is presented using 350 pb-1 of data from ppbar collisions at sqrt(s) = 1.96 TeV collected with the CDF II detector at the Fermilab Tevatron. The width is determined by normalizing predicted signal and background distributions to 230185 W candidates decaying to enu and munu in the transverse-mass region 50 < M_T < 90 GeV and then fitting the predicted shape to 6055 events in the high-M_T region, 90 < M_T < 200 GeV. The result is G_W = 2032 +/- 45 (stat.) +/- 57 (syst.) MeV, consistent with the standard model expectation.

Human review
References
How the literature uses it

10 arXiv papers cite this in 11 sentences

Each citing sentence is taken from the citing paper's LaTeX source and typed by Pith's classifier. A label appears at probability 0.8 or more (0.95 for support), a contest at 0.7 or more; the quoted words are the citing authors'. How each label was checked · JSON

Papers citing it · 6 sentences without a confident label

Uses its data or values 3 papers
  • The contribution in Eq. ([ref]) should be compared against the current experimental value for the $W$ width, dominated by measurements at the Tevatron [ref] , [equation] Given the agreement of this with SM expectations for $W→ℓν$ and $W→$hadrons, we limit the contribution of the $μνV$ mode to the $W$ width to twice its error, leading to a branching [equation] at $2σ$.

    Constraints on muon-specific dark forces · High-energy constraints · 0.97

  • Including also the recent result on $$ based on Run-II data by CDF [ref] , the combined results are: $= 80429±39$, $= 2078±87$.[The combined Tevatron result quoted for $$ and used here does not take into account the very recently published CDF result based on Run-II data, $= 2.032±0.073$ [ref] .] Combining these results with the preliminary combination [ref] ,

    Precision Electroweak Measurements and Constraints on the Standard Model · Measurements · 0.90

  • CDF has the most precise measurement of this quantity, based on 350 pb$^-1$ of data: $Γ_W$ = 2032 $±$ 71 MeV/$c^2$, in good agreement with SM predictions [ref] .

    Electroweak and Top Physics at the Tevatron and Indirect Higgs Limits · Direct $W$ Width Measurement · 0.91

Compares with it 1 paper

What it cites · 1 sentence without a confident label

Uses data or values from 1 paper
Cites as background 1 paper
  • The components of the CDF II detector relevant to this analysis are described briefly here; a more complete description can be found elsewhere [ref] .

    First Run II Measurement of the W Boson Mass · Introduction · 0.88

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.