Pith. Sign in

RECORD

Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: comparison of single and double phase operation

Instrumentation and Detectors · Submitted 16 Jul 2009

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.

how it is stated · hedged possibility 0.37 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID0907.2944 (version 1)
Pith IDX4JGIY3A, Pith's permanent record of this paper and its review
CitationA.Badertscher, A.Marchionni, A.Rubbia, D.Lussi, F.Resnati, G.Natterer, L.Knecht, M.Laffranchi, P.Otiougova, T.Viant. "Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: comparison of single and double phase operation." arXiv:0907.2944 (2009). https://pith.science/paper/X4JGIY3A
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 5,703 input tokens, $0.0002 reported.

What the abstract itself states, as probabilities: claims first 0.07 · states limitation 0.66 · human participants 0.02 · controlled comparison 0.17 · randomized assignment 0.01 · states quantitative result 0.74 · compares with prior results 0.29 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM where the multiplication occurs. Moving charges induce a signal on the anode and on the LEM electrodes. The orthogonally segmented upper face of the upper LEM and anode permit the reconstruction of X-Y spatial coordinates of ionizing events. The detector is equipped with a Photo Multiplier Tube immersed in liquid for triggering the ionizing events and an argon purification circuit to ensure long drift paths. Cosmic muon tracks have been recorded and further characterization of the detector is ongoing. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. contribution 0.69 0.97 0.05 asserted 1.00
s1 The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM where the multiplication occurs. method 0.98 0.37 0.03 asserted 1.00
s2 Moving charges induce a signal on the anode and on the LEM electrodes. method 0.99 0.29 0.02 asserted 1.00
s3 The orthogonally segmented upper face of the upper LEM and anode permit the reconstruction of X-Y spatial coordinates of ionizing events. method 0.99 0.72 0.03 asserted 1.00
s4 The detector is equipped with a Photo Multiplier Tube immersed in liquid for triggering the ionizing events and an argon purification circuit to ensure long drift paths. method 0.99 0.85 0.03 asserted 1.00
s5 Cosmic muon tracks have been recorded and further characterization of the detector is ongoing. result 0.86 0.95 0.05 asserted 1.00
s6 We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices. interpretation 0.99 0.23 0.77 hedged possibility 0.37

What kind of paper the classifier reports this is: method or tool 0.60 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM where the multiplication occurs. Moving charges induce a signal on the anode and on the LEM electrodes. The orthogonally segmented upper face of the upper LEM and anode permit the reconstruction of X-Y spatial coordinates of ionizing events. The detector is equipped with a Photo Multiplier Tube immersed in liquid for triggering the ionizing events and an argon purification circuit to ensure long drift paths. Cosmic muon tracks have been recorded and further characterization of the detector is ongoing. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.

Human review
How the literature uses it

14 arXiv papers cite this in 25 sentences

Each citing sentence is taken from the citing paper's LaTeX source and typed by Pith's classifier. A label appears at probability 0.8 or more (0.95 for support), a contest at 0.7 or more; the quoted words are the citing authors'. How each label was checked · JSON

Papers whose main result relates to this one's

Found among the papers closest to this one by title and main claim. Pith's classifier compared each pair's main results and a second model family confirmed the relation; checked against two further families, shown conflicts agreed 118 times in 120 and shown same results 218 times in 239. The quoted sentence is the other paper's main claim.

States the same result 1 paper

Papers citing it · 17 sentences without a confident label

Uses its method or tool 3 papers
Compares with it 1 paper
Cites it as support 2 papers
  • This significantly improves the event reconstruction quality with a lower energy deposition threshold and a better resolution per volumetric pixel (voxel) compared to a conventional single-phase LAr TPC [ref] .

    Future liquid Argon detectors · Double phase readout: the LAr LEM TPC · 0.98

  • Both [ref] and [ref] stress the importance of purifying or removing the argon gas during the initial phase of the detector cooling, because it is possibly contaminated by outgassing.

    R&D for Future 100 kton Scale Liquid Argon Detectors · Argon purity · 0.96

Cites it as background 1 paper

What it cites · 3 sentences without a confident label

Cites as background 1 paper

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.