Pith. sign in

REVIEW 1 cited by

A generalised porosity formalism for isotropic and anisotropic effective opacity and its effects on X-ray line attenuation in clumped O star winds

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1111.1762 v1 pith:EDMWPTP3 submitted 2011-11-07 astro-ph.SR

classification astro-ph.SR
keywords lineopacityporosityclumpsx-rayanisotropicclumpclumping
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

We present a generalised formalism for treating the porosity-associated reduction in continuum opacity that occurs when individual clumps in a stochastic medium become optically thick. We consider geometries resulting in either isotropic or anisotropic effective opacity, and, in addition to an idealised model in which all clumps have the same local overdensity and scale, we also treat an ensemble of clumps with optical depths set by Markovian statistics. This formalism is then applied to the specific case of bound-free absorption of X-rays in hot star winds, a process not directly affected by clumping in the optically thin limit. We find that the Markov model gives surprisingly similar results to those found previously for the single clump model, suggesting that porous opacity is not very sensitive to details of the assumed clump distribution function. Further, an anisotropic effective opacity favours escape of X-rays emitted in the tangential direction (the `venetian blind' effect), resulting in a 'bump' of higher flux close to line centre as compared to profiles computed from isotropic porosity models. We demonstrate how this characteristic line shape may be used to diagnose the clump geometry, and we confirm previous results that for optically thick clumping to significantly influence X-ray line profiles, very large porosity lengths, defined as the mean free path between clumps, are required. Moreover, we present the first X-ray line profiles computed directly from line-driven instability simulations using a 3-D patch method, and find that porosity effects from such models also are very small. This further supports the view that porosity has, at most, a marginal effect on X-ray line diagnostics in O stars, and therefore that these diagnostics do indeed provide a good `clumping insensitive' method for deriving O star mass-loss rates.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Stellar winds of O-type stars traced by high ionization fine-structure emission lines with JWST/MIRI

    astro-ph.SR 2026-06 unverdicted novelty 7.0 of 10

    JWST/MIRI detects [Ne V] 14.3 micron emission from O-star winds in 5 of 22 observed stars, enabling wind speed and mass-loss rate estimates even in weak-wind regimes.

Pith tools