Pith. sign in

REVIEW 2 cited by

High-fidelity radio astronomical polarimetry using a millisecond pulsar as a polarized reference source

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1212.3446 v1 pith:LPIMQOEZ submitted 2012-12-14 astro-ph.IM

classification astro-ph.IM
keywords timetimingpulsararrayarrivalexperimentinstrumentalpulsars
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

A new method of polarimetric calibration is presented in which the instrumental response is derived from regular observations of PSR J0437-4715 based on the assumption that the mean polarized emission from this millisecond pulsar remains constant over time. The technique is applicable to any experiment in which high-fidelity polarimetry is required over long time scales; it is demonstrated by calibrating 7.2 years of high-precision timing observations of PSR J1022+1001 made at the Parkes Observatory. Application of the new technique followed by arrival time estimation using matrix template matching yields post-fit residuals with an uncertainty-weighted standard deviation of 880 ns, two times smaller than that of arrival time residuals obtained via conventional methods of calibration and arrival time estimation. The precision achieved by this experiment yields the first significant measurements of the secular variation of the projected semi-major axis, the precession of periastron, and the Shapiro delay; it also places PSR J1022+1001 among the ten best pulsars regularly observed as part of the Parkes Pulsar Timing Array (PPTA) project. It is shown that the timing accuracy of a large fraction of the pulsars in the PPTA is currently limited by the systematic timing error due to instrumental polarization artifacts. More importantly, long-term variations of systematic error are correlated between different pulsars, which adversely affects the primary objectives of any pulsar timing array experiment. These limitations may be overcome by adopting the techniques presented in this work, which relax the demand for instrumental polarization purity and thereby have the potential to reduce the development cost of next-generation telescopes such as the Square Kilometre Array.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. The SKAO Pulsar Timing Array

    astro-ph.IM 2026-07 accept novelty 3.5 of 10

    An SKAO PTA with ~174 millisecond pulsars can dominate nanohertz GW sensitivity within four years and enable continuous-wave detections plus anisotropy maps of the gravitational-wave background.

  2. Unlocking the hidden potential of pulsar astronomy

    astro-ph.IM 2025-06 conditional novelty 3.0 of 10

    This review and feasibility study shows that compact radio receivers can detect bright pulsars for navigation, timing, randomness, and space weather applications, with a 4-meter dish potentially achieving 10 km self-l...

Pith tools