Pith. sign in

REVIEW 1 cited by

High precision astrometry with a diffractive pupil telescope

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1304.0370 v1 pith:HPDGSDRD submitted 2013-04-01 astro-ph.IM

classification astro-ph.IM
keywords astrometricspikesfieldstarsastrometrybackgrounddiffractionhigh
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Astrometric detection and mass determination of Earth-mass exoplanets requires sub-microarcsec accuracy, which is theoretically possible with an imaging space telescope using field stars as an astrometric reference. The measurement must however overcome astrometric distortions which are much larger than the photon noise limit. To address this issue, we propose to generate faint stellar diffraction spikes using a two-dimensional grid of regularly spaced small dark spots added to the surface of the primary mirror (PM). Accurate astrometric motion of the host star is obtained by comparing the position of the spikes to the background field stars. The spikes do not contribute to scattered light in the central part of the field and therefore allow unperturbed coronagraphic observation of the star's immediate surrounding. Because the diffraction spikes are created on the PM and imaged on the same focal plane detector as the background stars, astrometric distortions affect equally the diffraction spikes and the background stars, and are therefore calibrated. We describe the technique, detail how the data collected by the wide-field camera are used to derive astrometric motion, and identify the main sources of astrometric error using numerical simulations and analytical derivations. We find that the 1.4 m diameter telescope, 0.3 sq.deg field we adopt as a baseline design achieves 0.2 microarcsec single measurement astrometric accuracy. The diffractive pupil concept thus enables sub-microarcsec astrometry without relying on the accurate pointing, external metrology or high stability hardware required with previously proposed high precision astrometry concepts.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Searching for Habitable Exoplanets with Relative Astrometry (SHERA). I. The Case for Searching for Planets in Binary Star Systems

    astro-ph.EP 2026-08 conditional novelty 4.0 of 10

    SHERA is a proposed Small Explorer astrometry mission that could detect rocky habitable-zone planets around 14 nearby Sun-like stars in binary systems using microarcsecond relative astrometry.

Pith tools