Pith. Sign in

RECORD

A 31T split-pair pulsed magnet for single crystal x-ray diffraction at low temperature

Strongly Correlated Electrons · Submitted 4 Mar 2014

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31T and at low temperature down to 1.5 K.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1403.0722 (version 1)
Pith IDRJMSKIPM, Pith's permanent record of this paper and its review
CitationA. Zitouni, C. Detlefs, F. Duc, G. L. J. A. Rikken, J. B\'eard, J. Billette, J.P. Nicolin, L. Zhang, M. Lesourd, M. Nardone, P. Delescluse, P. Frings, T. Roth, X. Fabr\`eges. "A 31T split-pair pulsed magnet for single crystal x-ray diffraction at low temperature." arXiv:1403.0722 (2014). https://pith.science/paper/RJMSKIPM
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 3,709 input tokens, $0.0002 reported.

What the abstract itself states, as probabilities: claims first 0.05 · states limitation 0.33 · human participants 0.02 · controlled comparison 0.02 · randomized assignment 0.01 · states quantitative result 0.97 · compares with prior results 0.06 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31T and at low temperature down to 1.5 K. The apparatus consists of a split-pair magnet, a liquid nitrogen bath to cool the pulsed coil, and a helium cryostat allowing sample temperatures from 1.5 up to 250 K. Using a 1.15MJ mobile generator, magnetic field pulses of 60 ms length were generated in the magnet, with a rise time of 16.5 ms and a repetition rate of 2 pulses/hour at 31 T. The setup was validated for single crystal diffraction on the ESRF beamline ID06.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31T and at low temperature down to 1.5 K. contribution 1.00 0.95 0.57 asserted 1.00
s1 The apparatus consists of a split-pair magnet, a liquid nitrogen bath to cool the pulsed coil, and a helium cryostat allowing sample temperatures from 1.5 up to 250 K. method 0.99 0.73 0.06 asserted 1.00
s2 Using a 1.15MJ mobile generator, magnetic field pulses of 60 ms length were generated in the magnet, with a rise time of 16.5 ms and a repetition rate of 2 pulses/hour at 31 T. method 0.98 0.92 0.09 asserted 1.00
s3 The setup was validated for single crystal diffraction on the ESRF beamline ID06. result 0.59 0.89 0.19 asserted 1.00

What kind of paper the classifier reports this is: method or tool 1.00 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31T and at low temperature down to 1.5 K. The apparatus consists of a split-pair magnet, a liquid nitrogen bath to cool the pulsed coil, and a helium cryostat allowing sample temperatures from 1.5 up to 250 K. Using a 1.15MJ mobile generator, magnetic field pulses of 60 ms length were generated in the magnet, with a rise time of 16.5 ms and a repetition rate of 2 pulses/hour at 31 T. The setup was validated for single crystal diffraction on the ESRF beamline ID06.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.