RECORD
The electron mass from $g$-factor measurements on hydrogen-like carbon $^{12}$C$^{5+}$
Atomic Physics · Submitted 15 Apr 2016
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value. The underlying measurement principle combines a high-precision measurement of the Larmor-to-cyclotron frequency ratio on a single hydrogen-like carbon ion in a Penning trap with a corresponding very accurate $g$-factor calculation. Here, we present the measurement results in detail, including a comprehensive discussion of the systematic shifts and their uncertainties. A special focus is set on the various sources of phase jitters, which are essential for the understanding of the applied line-shape model for the $g$-factor resonance.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value. | result 1.00 | 0.92 | 0.93 | asserted 1.00 |
| s1 | The underlying measurement principle combines a high-precision measurement of the Larmor-to-cyclotron frequency ratio on a single hydrogen-like carbon ion in a Penning trap with a corresponding very accurate $g$-factor calculation. | method 1.00 | 0.85 | 0.05 | asserted 1.00 |
| s2 | Here, we present the measurement results in detail, including a comprehensive discussion of the systematic shifts and their uncertainties. | contribution 0.99 | 0.83 | 0.03 | asserted 0.95 |
| s3 | A special focus is set on the various sources of phase jitters, which are essential for the understanding of the applied line-shape model for the $g$-factor resonance. | contribution 0.51 | 0.58 | 0.02 | asserted 0.99 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value. The underlying measurement principle combines a high-precision measurement of the Larmor-to-cyclotron frequency ratio on a single hydrogen-like carbon ion in a Penning trap with a corresponding very accurate $g$-factor calculation. Here, we present the measurement results in detail, including a comprehensive discussion of the systematic shifts and their uncertainties. A special focus is set on the various sources of phase jitters, which are essential for the understanding of the applied line-shape model for the $g$-factor resonance.
Human review
How the literature uses it
1 arXiv paper cite this in 1 sentence
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.