The authors' main claim Overall, the relative number of criteria achieved was higher for automated planning versus clinical (17 vs 8) and automated planning demonstrated increased sparing for organs at risk (52 vs 44) and better target coverage/uniformity (41 vs 31).
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present an atlas-based approach which learns a dose prediction model for each patient (atlas) in a training database, and then learns to match novel patients to the most relevant atlases. The method creates a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces any requirement for specifying dose-volume objectives for conveying the goals of treatment planning. A probabilistic dose distribution is inferred from the most relevant atlases, and is scalarized using a conditional random field to determine the most likely spatial distribution of dose to yield a specific dose prior (histogram) for relevant regions of interest. Voxel-based dose mimicking then converts the predicted dose distribution to a deliverable treatment plan dose distribution. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients. Our preliminary results are promising; automated planning achieved a higher number of dose evaluation criteria in 7 patients and an equal number in 4 patients compared with clinical. Overall, the relative number of criteria achieved was higher for automated planning versus clinical (17 vs 8) and automated planning demonstrated increased sparing for organs at risk (52 vs 44) and better target coverage/uniformity (41 vs 31).
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. | background 1.00 | 0.04 | 0.02 | asserted 1.00 |
| s1 | We present an atlas-based approach which learns a dose prediction model for each patient (atlas) in a training database, and then learns to match novel patients to the most relevant atlases. | method 0.66 | 0.91 | 0.03 | asserted 0.99 |
| s2 | The method creates a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces any requirement for specifying dose-volume objectives for conveying the goals of treatment planning. | method 0.90 | 0.74 | 0.05 | asserted 1.00 |
| s3 | A probabilistic dose distribution is inferred from the most relevant atlases, and is scalarized using a conditional random field to determine the most likely spatial distribution of dose to yield a specific dose prior (histogram) for relevant regions of interest. | method 1.00 | 0.85 | 0.03 | asserted 1.00 |
| s4 | Voxel-based dose mimicking then converts the predicted dose distribution to a deliverable treatment plan dose distribution. | method 1.00 | 0.74 | 0.03 | asserted 1.00 |
| s5 | In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. | method 0.56 | 0.93 | 0.02 | asserted 0.96 |
| s6 | We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients. | method 0.96 | 0.97 | 0.03 | asserted 0.98 |
| s7 | Our preliminary results are promising; automated planning achieved a higher number of dose evaluation criteria in 7 patients and an equal number in 4 patients compared with clinical. | result 0.97 | 0.97 | 0.30 | asserted 0.71 |
| s8 | Overall, the relative number of criteria achieved was higher for automated planning versus clinical (17 vs 8) and automated planning demonstrated increased sparing for organs at risk (52 vs 44) and better target coverage/uniformity (41 vs 31). | result 1.00 | 0.96 | 0.68 | asserted 1.00 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present an atlas-based approach which learns a dose prediction model for each patient (atlas) in a training database, and then learns to match novel patients to the most relevant atlases. The method creates a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces any requirement for specifying dose-volume objectives for conveying the goals of treatment planning. A probabilistic dose distribution is inferred from the most relevant atlases, and is scalarized using a conditional random field to determine the most likely spatial distribution of dose to yield a specific dose prior (histogram) for relevant regions of interest. Voxel-based dose mimicking then converts the predicted dose distribution to a deliverable treatment plan dose distribution. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients. Our preliminary results are promising; automated planning achieved a higher number of dose evaluation criteria in 7 patients and an equal number in 4 patients compared with clinical. Overall, the relative number of criteria achieved was higher for automated planning versus clinical (17 vs 8) and automated planning demonstrated increased sparing for organs at risk (52 vs 44) and better target coverage/uniformity (41 vs 31).
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.