Pith. Sign in

RECORD

Strength and stability of active ligand-receptor bonds: a microtubule attached to a wall by molecular motor tethers

Subcellular Processes · Submitted 16 Oct 2016

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The simulation results reveal that the MT-cell attachment behaves as a catch-bond or slip-bond depending on system parameters.

how it is stated · asserted 0.98 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1610.04835 (version 2)
Pith IDRKIC7GMP, Pith's permanent record of this paper and its review
CitationDebashish Chowdhury (IIT Kanpur, Dipanwita Ghanti (IIT Kanpur, India), Livermore, Raymond W. Friddle (Sandia National Lab, USA). "Strength and stability of active ligand-receptor bonds: a microtubule attached to a wall by molecular motor tethers." arXiv:1610.04835 (2016). https://pith.science/paper/RKIC7GMP
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 5,015 input tokens.

What the abstract itself states, as probabilities: claims first 0.06 · states limitation 0.09 · human participants 0.02 · controlled comparison 0.05 · randomized assignment 0.01 · states quantitative result 0.06 · compares with prior results 0.08 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v2. Results and the main claim are underlined; .

We develop a stochastic kinetic model of a pre-formed attachment of a mictrotuble (MT) with a cell cortex, in which the MT is tethered to the cell by a group of active motor proteins. Such an attachment is a particularly unique case of ligand-receptor bonds: The MT ligand changes its length (and thus binding sites) with time by polymerization-depolymerization kinetics, while multiple motor receptors tend to walk actively along the MT length. These processes, combined with force-mediated unbinding of the motors, result in an elaborate behavior of the MT connection to the cell cortex. We present results for the strength and lifetime of the system through the well-established force-clamp and force-ramp protocols when external tension is applied to the MT. The simulation results reveal that the MT-cell attachment behaves as a catch-bond or slip-bond depending on system parameters. We provide analytical approximations of the lifetime and discuss implications of our results on in-vitro experiments.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 We develop a stochastic kinetic model of a pre-formed attachment of a mictrotuble (MT) with a cell cortex, in which the MT is tethered to the cell by a group of active motor proteins. contribution 0.50 0.93 0.04 asserted 0.97
s1 Such an attachment is a particularly unique case of ligand-receptor bonds: The MT ligand changes its length (and thus binding sites) with time by polymerization-depolymerization kinetics, while multiple motor receptors tend to walk actively along the MT length. background 0.80 0.13 0.05 asserted 1.00
s2 These processes, combined with force-mediated unbinding of the motors, result in an elaborate behavior of the MT connection to the cell cortex. result 0.36 0.41 0.08 asserted 0.99
s3 We present results for the strength and lifetime of the system through the well-established force-clamp and force-ramp protocols when external tension is applied to the MT. method 0.72 0.89 0.07 asserted 0.91
s4 The simulation results reveal that the MT-cell attachment behaves as a catch-bond or slip-bond depending on system parameters. result 1.00 0.94 0.64 asserted 0.98
s5 We provide analytical approximations of the lifetime and discuss implications of our results on in-vitro experiments. contribution 0.87 0.94 0.11 asserted 0.97

What kind of paper the classifier reports this is: simulation study 0.79 · evidence from simulation or computation 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v2
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

We develop a stochastic kinetic model of a pre-formed attachment of a mictrotuble (MT) with a cell cortex, in which the MT is tethered to the cell by a group of active motor proteins. Such an attachment is a particularly unique case of ligand-receptor bonds: The MT ligand changes its length (and thus binding sites) with time by polymerization-depolymerization kinetics, while multiple motor receptors tend to walk actively along the MT length. These processes, combined with force-mediated unbinding of the motors, result in an elaborate behavior of the MT connection to the cell cortex. We present results for the strength and lifetime of the system through the well-established force-clamp and force-ramp protocols when external tension is applied to the MT. The simulation results reveal that the MT-cell attachment behaves as a catch-bond or slip-bond depending on system parameters. We provide analytical approximations of the lifetime and discuss implications of our results on in-vitro experiments.

Human review

Discussion