Pith. Sign in

RECORD

The Use of KF Style Flanges In Low Particulate Applications

Accelerator Physics · Submitted 3 Jan 2017

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim This document will describe the tests used to compare the particles generated using the assembly of the, widely accepted for "particle free" use, conflat flange to the proposed KF style flange, and demonstrate that KF flanges produce comparable or even less particles.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1701.00842 (version 1)
Pith IDH3K6KYVQ, Pith's permanent record of this paper and its review
CitationC. Baffes, D. Franck, J. Angelo, K.R. Kendziora, R. Kellett (Fermilab). "The Use of KF Style Flanges In Low Particulate Applications." arXiv:1701.00842 (2017). https://pith.science/paper/H3K6KYVQ
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 3,676 input tokens.

What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.08 · human participants 0.02 · controlled comparison 0.91 · randomized assignment 0.01 · states quantitative result 0.05 · compares with prior results 0.92 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

As SCRF particle accelerator technology advances the need for "low particulate" and "particle free" vacuum systems becomes greater and greater. In the course of the operation of these systems, there comes a time when various instruments have to be temporarily attached for diagnostic purposes: RGAs, leak detectors, and additional pumps. In an effort to make the additions of these instruments easier and more time effective, we propose to use KF style flanges for these types of temporary diagnostic connections. This document will describe the tests used to compare the particles generated using the assembly of the, widely accepted for "particle free" use, conflat flange to the proposed KF style flange, and demonstrate that KF flanges produce comparable or even less particles.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 As SCRF particle accelerator technology advances the need for "low particulate" and "particle free" vacuum systems becomes greater and greater. background 1.00 0.05 0.02 asserted 1.00
s1 In the course of the operation of these systems, there comes a time when various instruments have to be temporarily attached for diagnostic purposes: RGAs, leak detectors, and additional pumps. background 1.00 0.11 0.02 asserted 0.99
s2 In an effort to make the additions of these instruments easier and more time effective, we propose to use KF style flanges for these types of temporary diagnostic connections. contribution 0.92 0.26 0.07 asserted 0.46
s3 This document will describe the tests used to compare the particles generated using the assembly of the, widely accepted for "particle free" use, conflat flange to the proposed KF style flange, and demonstrate that KF flanges produce comparable or even less particles. contribution 0.81 0.91 0.88 asserted 1.00

What kind of paper the classifier reports this is: empirical study 0.92 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

As SCRF particle accelerator technology advances the need for "low particulate" and "particle free" vacuum systems becomes greater and greater. In the course of the operation of these systems, there comes a time when various instruments have to be temporarily attached for diagnostic purposes: RGAs, leak detectors, and additional pumps. In an effort to make the additions of these instruments easier and more time effective, we propose to use KF style flanges for these types of temporary diagnostic connections. This document will describe the tests used to compare the particles generated using the assembly of the, widely accepted for "particle free" use, conflat flange to the proposed KF style flange, and demonstrate that KF flanges produce comparable or even less particles.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.