Pith. Sign in

RECORD

A biomechanical breast model evaluated with respect to MRI data collected in three different positions

Medical Physics · Submitted 26 Nov 2018

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The Hausdorff distance between estimated and measured breast geometries for prone, supine and supine tilted configurations is equal to 2.17 mm, 1.72mm and 5.90mm respectively.Interpretation: A subject-specific breast model allows a better characterization of breast mechanics.

how it is stated · asserted 0.96 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1811.10221 (version 1)
Pith IDX7PZRC5A, Pith's permanent record of this paper and its review
CitationAnna M\^ira, Ann-Katherine Carton (GE Healthcare), Serge Muller (GE Healthcare), Yohan Payan (TIMC-IMAG-GMCAO). "A biomechanical breast model evaluated with respect to MRI data collected in three different positions." arXiv:1811.10221 (2018). https://pith.science/paper/X7PZRC5A
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 8,294 input tokens.

What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.98 · human participants 0.89 · controlled comparison 0.08 · randomized assignment 0.01 · states quantitative result 0.99 · compares with prior results 0.19 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

Background: Mammography is a specific type of breast imaging that uses low-dose X-rays to detect cancer in early stage. During the exam, the women breast is compressed between two plates in order to even out the breast thickness and to spread out the soft tissues. This technique improves exam quality but can be uncomfortable for the patient. The perceived discomfort can be assessed by the means of a breast biomechanical model. Alternative breast compression techniques may be computationally investigated trough finite elements simulations.Methods: The aim of this work is to develop and evaluate a new biomechanical Finite Element (FE) breast model. The complex breast anatomy is considered including adipose and glandular tissues, muscle, skin, suspensory ligaments and pectoral fascias. Material hyper-elasticity is modeled using the Neo-Hookean material models. The stress-free breast geometry and subject-specific constitutive models are derived using tissues deformations measurements from MR images.Findings: The breast geometry in three breast configurations were computed using the breast stress-free geometry together with the estimated set of equivalent Young's modulus (Ebreast_r=0.3 kPa, Ebreast_l=0.2 kPa, Eskin=4 kPa, Efascia=120 kPa). The Hausdorff distance between estimated and measured breast geometries for prone, supine and supine tilted configurations is equal to 2.17 mm, 1.72mm and 5.90mm respectively.Interpretation: A subject-specific breast model allows a better characterization of breast mechanics. However, the model presents some limitations when estimating the supine tilted breast configuration. The results show clearly the difficulties to characterize soft tissues mechanics at large strain ranges with Neo-Hookean material models.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 Background: Mammography is a specific type of breast imaging that uses low-dose X-rays to detect cancer in early stage. background 1.00 0.03 0.01 asserted 1.00
s1 During the exam, the women breast is compressed between two plates in order to even out the breast thickness and to spread out the soft tissues. background 1.00 0.05 0.02 asserted 1.00
s2 This technique improves exam quality but can be uncomfortable for the patient. background 1.00 0.05 0.02 asserted 0.98
s3 The perceived discomfort can be assessed by the means of a breast biomechanical model. background 0.88 0.08 0.03 asserted 0.72
s4 Alternative breast compression techniques may be computationally investigated trough finite elements simulations.Methods: The aim of this work is to develop and evaluate a new biomechanical Finite Element (FE) breast model. contribution 0.77 0.29 0.02 hedged possibility 0.81
s5 The complex breast anatomy is considered including adipose and glandular tissues, muscle, skin, suspensory ligaments and pectoral fascias. method 0.97 0.78 0.02 asserted 1.00
s6 Material hyper-elasticity is modeled using the Neo-Hookean material models. method 1.00 0.78 0.02 asserted 1.00
s7 The stress-free breast geometry and subject-specific constitutive models are derived using tissues deformations measurements from MR images.Findings: The breast geometry in three breast configurations were computed using the breast stress-free geometry together with the estimated set of equivalent Young's modulus (Ebreast_r=0.3 kPa, Ebreast_l=0.2 kPa, Eskin=4 kPa, Efascia=120 kPa). result 0.93 0.94 0.09 asserted 1.00
s8 The Hausdorff distance between estimated and measured breast geometries for prone, supine and supine tilted configurations is equal to 2.17 mm, 1.72mm and 5.90mm respectively.Interpretation: A subject-specific breast model allows a better characterization of breast mechanics. result 0.96 0.94 0.30 asserted 0.96
s9 However, the model presents some limitations when estimating the supine tilted breast configuration. limitation 0.99 0.85 0.09 asserted 0.91
s10 The results show clearly the difficulties to characterize soft tissues mechanics at large strain ranges with Neo-Hookean material models. limitation 0.58 0.86 0.22 asserted 1.00

What kind of paper the classifier reports this is: simulation study 0.65 · evidence from simulation or computation 0.98.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

Background: Mammography is a specific type of breast imaging that uses low-dose X-rays to detect cancer in early stage. During the exam, the women breast is compressed between two plates in order to even out the breast thickness and to spread out the soft tissues. This technique improves exam quality but can be uncomfortable for the patient. The perceived discomfort can be assessed by the means of a breast biomechanical model. Alternative breast compression techniques may be computationally investigated trough finite elements simulations.Methods: The aim of this work is to develop and evaluate a new biomechanical Finite Element (FE) breast model. The complex breast anatomy is considered including adipose and glandular tissues, muscle, skin, suspensory ligaments and pectoral fascias. Material hyper-elasticity is modeled using the Neo-Hookean material models. The stress-free breast geometry and subject-specific constitutive models are derived using tissues deformations measurements from MR images.Findings: The breast geometry in three breast configurations were computed using the breast stress-free geometry together with the estimated set of equivalent Young's modulus (Ebreast_r=0.3 kPa, Ebreast_l=0.2 kPa, Eskin=4 kPa, Efascia=120 kPa). The Hausdorff distance between estimated and measured breast geometries for prone, supine and supine tilted configurations is equal to 2.17 mm, 1.72mm and 5.90mm respectively.Interpretation: A subject-specific breast model allows a better characterization of breast mechanics. However, the model presents some limitations when estimating the supine tilted breast configuration. The results show clearly the difficulties to characterize soft tissues mechanics at large strain ranges with Neo-Hookean material models.

Human review
How the literature uses it

1 arXiv paper cite this in 2 sentences

Each citing sentence is taken from the citing paper's LaTeX source and typed by Pith's classifier. A label appears at probability 0.8 or more (0.95 for support), a contest at 0.7 or more; the quoted words are the citing authors'. How each label was checked · JSON

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.