Pith. sign in

REVIEW 1 cited by

Additively manufactured ultra-high vacuum chamber below $10^{-10}$ mbar

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1903.07708 v3 pith:XCZDULTL submitted 2019-03-15 quant-ph physics.app-ph

classification quant-phphysics.app-ph
keywords manufacturedmassadditivelychambermbartechnologiesbelowcold
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Metal-based additive manufacturing (AM) represents a paradigm change in engineering and production methods across multiple industries and sectors. AM methods enable mass reduction and performance optimisation well beyond that achievable via conventional manufacturing, thereby impacting significantly on aerospace and space technologies. Technologies relying on high and ultra-high vacuum (UHV), such as x-ray photo-electron spectroscopy, photo-sensors, cameras and cryostats, could also benefit greatly from AM. Despite recent advances in AM processing of metals, additively manufactured UHV chambers have so far not been achieved. Reducing the mass of UHV equipment is particularly critical for the development of portable cold atom systems, which are expected to underpin the next generation of sensing and timekeeping technologies and to allow novel space-based sensors for fundamental research. We demonstrate here an additively manufactured UHV chamber reaching a pressure below $10^{-10}$ mbar, enabling a cloud of cold $^{85}$Rb atoms to be trapped - the starting point for many precision timekeeping and sensing devices. The chamber is manufactured from aluminium alloy AlSi10Mg by laser powder bed fusion and has a mass of less than a third of a commercially-available equivalent. Outgassing analysis based on mass spectrometry was performed and it was demonstrated that even without active pumping the system remains in the $10^{-9}$ mbar regime for up to 48 hours.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Qubit operations using a modular optical system engineered with PyOpticL: a code-to-CAD optical layout tool

    quant-ph 2025-01 conditional novelty 7.0 of 10

    PyOpticL is an open-source code-to-CAD optical layout tool with dynamic beam-path routing, demonstrated on a strontium trapped-ion system that achieved 99.9% single-qubit gate fidelity.

Pith tools