Pith. Sign in

RECORD

VADER: a VAriable Dose-rate External 137Cs irradiatoR for internal emitter and low dose rate studies

Medical Physics · Submitted 10 May 2019

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The VADER (VAriable Dose-rate External Cs-137 irradiatoR) allows modeling these exposures, bypassing many of the problems inherent in internal emitter studies.

how it is stated · asserted 0.97 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1905.04169 (version 2)
Pith IDDNEU6DOE, Pith's permanent record of this paper and its review
CitationAlbert J. Fornace Jr., Carlos Bueno-Beti, David Cuniberti, David J. Brenner, Evangelia C. Laiakis, Gary W. Johnson, Guy Garty, Helen C. Turner, Lubomir B. Smilenov, Monica Pujol-Canadell, Peter F. Caracappa, Qi Wang, Robort Morton, Rompin Shih, Shad R. Morton, Shanaz A. Ghanhi, Simon K. Joseph, Thomas L. Morgan, Yanping Xu. "VADER: a VAriable Dose-rate External 137Cs irradiatoR for internal emitter and low dose rate studies." arXiv:1905.04169 (2019). https://pith.science/paper/DNEU6DOE
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 6,414 input tokens.

What the abstract itself states, as probabilities: claims first 0.05 · states limitation 0.11 · human participants 0.05 · controlled comparison 0.04 · randomized assignment 0.01 · states quantitative result 0.88 · compares with prior results 0.10 · mentions code or data availability 0.03.

The abstract, sentence by sentence

arXiv listing abstract v2. Results and the main claim are underlined; .

Beyond prompt irradiation, Cs-137 is likely to be the most biologically important agent released in many accidental (or malicious) radiation exposure scenarios. Cs-137 either can enter the food chain or be consumed or if present in the environment (e.g. fallout) can provide external irradiation. In either case, due to the high penetration of the 662 keV gamma rays emitted by Cs-137, the individual will be exposed to a uniform, whole body, irradiation at low dose rates. The VADER (VAriable Dose-rate External Cs-137 irradiatoR) allows modeling these exposures, bypassing many of the problems inherent in internal emitter studies. Making use of discarded Cs-137 brachytherapy seeds, the VADER can provide varying low dose rate irradiations at dose rates of 0.1 to 1.2 Gy/day. The VADER includes a mouse "hotel", designed to allow long term simultaneous residency of up to 15 mice. Two source platters containing ~250 mCi each of Cs-137 brachytherapy seeds are mounted above and below the cage and can be moved under computer control to provide constant low dose rate or a varying dose rate mimicking Cs biokinetics in mouse or man. We present the VADER design and characterization of its performance.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 Beyond prompt irradiation, Cs-137 is likely to be the most biologically important agent released in many accidental (or malicious) radiation exposure scenarios. background 1.00 0.07 0.05 hedged possibility 1.00
s1 Cs-137 either can enter the food chain or be consumed or if present in the environment (e.g. fallout) can provide external irradiation. background 1.00 0.04 0.03 hedged possibility 0.71
s2 In either case, due to the high penetration of the 662 keV gamma rays emitted by Cs-137, the individual will be exposed to a uniform, whole body, irradiation at low dose rates. background 1.00 0.07 0.05 asserted 0.98
s3 The VADER (VAriable Dose-rate External Cs-137 irradiatoR) allows modeling these exposures, bypassing many of the problems inherent in internal emitter studies. contribution 0.79 0.36 0.22 asserted 0.97
s4 Making use of discarded Cs-137 brachytherapy seeds, the VADER can provide varying low dose rate irradiations at dose rates of 0.1 to 1.2 Gy/day. method 0.93 0.79 0.09 asserted 0.85
s5 The VADER includes a mouse "hotel", designed to allow long term simultaneous residency of up to 15 mice. method 0.95 0.74 0.04 asserted 0.99
s6 Two source platters containing ~250 mCi each of Cs-137 brachytherapy seeds are mounted above and below the cage and can be moved under computer control to provide constant low dose rate or a varying dose rate mimicking Cs biokinetics in mouse or man. method 0.99 0.75 0.07 asserted 1.00
s7 We present the VADER design and characterization of its performance. contribution 1.00 0.87 0.10 asserted 0.94

What kind of paper the classifier reports this is: method or tool 1.00 · evidence from observation or experiment 0.95.

What was examined, and what was not

sources read
  • arXiv listing abstract v2
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

Beyond prompt irradiation, Cs-137 is likely to be the most biologically important agent released in many accidental (or malicious) radiation exposure scenarios. Cs-137 either can enter the food chain or be consumed or if present in the environment (e.g. fallout) can provide external irradiation. In either case, due to the high penetration of the 662 keV gamma rays emitted by Cs-137, the individual will be exposed to a uniform, whole body, irradiation at low dose rates. The VADER (VAriable Dose-rate External Cs-137 irradiatoR) allows modeling these exposures, bypassing many of the problems inherent in internal emitter studies. Making use of discarded Cs-137 brachytherapy seeds, the VADER can provide varying low dose rate irradiations at dose rates of 0.1 to 1.2 Gy/day. The VADER includes a mouse "hotel", designed to allow long term simultaneous residency of up to 15 mice. Two source platters containing ~250 mCi each of Cs-137 brachytherapy seeds are mounted above and below the cage and can be moved under computer control to provide constant low dose rate or a varying dose rate mimicking Cs biokinetics in mouse or man. We present the VADER design and characterization of its performance.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.