Pith. sign in

REVIEW 1 cited by

Accurate Retinal Vessel Segmentation via Octave Convolution Neural Network

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1906.12193 v8 pith:3O6Z6GYS submitted 2019-06-28 eess.IV cs.CV

classification eess.IVcs.CV
keywords octaveconvolutionconvolutionsproposedsegmentationunetvesseldiseases
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Retinal vessel segmentation is a crucial step in diagnosing and screening various diseases, including diabetes, ophthalmologic diseases, and cardiovascular diseases. In this paper, we propose an effective and efficient method for vessel segmentation in color fundus images using encoder-decoder based octave convolution networks. Compared with other convolution networks utilizing standard convolution for feature extraction, the proposed method utilizes octave convolutions and octave transposed convolutions for learning multiple-spatial-frequency features, thus can better capture retinal vasculatures with varying sizes and shapes. To provide the network the capability of learning how to decode multifrequency features, we extend octave convolution and propose a new operation named octave transposed convolution. A novel architecture of convolutional neural network, named as Octave UNet integrating both octave convolutions and octave transposed convolutions is proposed based on the encoder-decoder architecture of UNet, which can generate high resolution vessel segmentation in one single forward feeding without post-processing steps. Comprehensive experimental results demonstrate that the proposed Octave UNet outperforms the baseline UNet achieving better or comparable performance to the state-of-the-art methods with fast processing speed. Specifically, the proposed method achieves 0.9664 / 0.9713 / 0.9759 / 0.9698 accuracy, 0.8374 / 0.8664 / 0.8670 / 0.8076 sensitivity, 0.9790 / 0.9798 / 0.9840 / 0.9831 specificity, 0.8127 / 0.8191 / 0.8313 / 0.7963 F1 score, and 0.9835 / 0.9875 / 0.9905 / 0.9845 Area Under Receiver Operating Characteristic curve, on DRIVE, STARE, CHASE_DB1, and HRF datasets, respectively.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Deep Self-knowledge Distillation: A hierarchical supervised learning for coronary artery segmentation

    eess.IV 2025-09 conditional novelty 5.0 of 10

    Using the network's previous epoch as a teacher, with patch-level KL divergence and pixel-wise soft labels, improves coronary artery segmentation Dice by 2 to 4 points on XCAD and DCA1.

Pith tools