Pith. sign in

REVIEW

Iterative Motion Compensation reconstruction ultra-short TE(iMoCo UTE) for high resolution free breathing pulmonary MRI

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2001.11993 v1 pith:O5XGNBB7 submitted 2020-01-31 eess.IV physics.med-ph

Iterative Motion Compensation reconstruction ultra-short TE(iMoCo UTE) for high resolution free breathing pulmonary MRI

classification eess.IV physics.med-ph
keywords motionimocoreconstructioncompensationresolveddatalungreconstructed
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

Purpose, To develop a high scanning efficiency, motion corrected imaging strategy for free-breathing pulmonary MRI by combining a motion compensation reconstruction with a UTE acquisition, called iMoCo UTE. Methods, An optimized golden angle ordering radial UTE sequence was used to continuously acquire data for 5 minutes. All readouts were grouped to different respiratory motion states based on self-navigator signals, then motion resolved data was reconstructed by XD Golden angle RAdial Sparse Parallel reconstruction (XD GRASP). One state from the motion resolved images was selected as a reference, and motion fields from the other states to the reference were derived via non-rigid registration. Finally, all motion resolved data and motion fields were reconstructed by using an iterative motion compensation reconstruction with a total generalized variation sparse constraint. Results, The iMoCo UTE strategy was evaluated in volunteers and non-sedated pediatric patient(4-6 y/o) studies. Images reconstructed with iMoCo UTE provided sharper anatomical lung structures, and higher apparent SNR and CNR, compared to using other motion correction strategies, such as soft-gating, motion resolved reconstruction, and non-rigid motion compensation(MoCo). iMoCo UTE also showed promising results in an infant study. Conclusions, The proposed iMoCo UTE combines self-navigation, motion modeling, and a compressed sensing reconstruction to increase scan efficiency, SNR, and reduce respiratory motion in lung MRI. This proposed strategy shows improvements in free breathing lung MRI scans, especially in very challenging application situations, such as pediatric MRI studies.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.