Pith. sign in

REVIEW 3 cited by

Measurements of strong magnetic fields in umbra of sunspots: Crimea vs Mt. Wilson

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2003.12889 v1 pith:GDSIJYMQ submitted 2020-03-28 astro-ph.SR

classification astro-ph.SR
keywords magneticmeasurementswilsoncrimeanexceedfieldsaccordingbeen
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

The comparative analysis for 1324 measurements of the corresponding sunspot magnetic fields with B > 2.5 kG (according to Crimean data) obtained at Crimean and Mt. Wilson observatories from 2010 to 2017 has been carried out. It has been shown that the difference between measurements can exceed 1 kG in some cases. The averaged values of the magnetic field are equal to 2759 G (Crimea) and 2196 G (Mt. Wilson). The maximum sunspot magnetic field measured at Mt. Wilson does not reach 2.7 kG while according to Crimean data it can exceed 4.0 kG. The correlation coefficient between measurements of magnetic fields in different observatories does not exceed 0.22. The probable reasons of significant discrepancies are discussed.

Discussion (0). Sign in to comment.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Laskar's frequency map analysis revisited

    math.DS 2026-08 conditional novelty 6.0 of 10

    Frequency map analysis converges with error O(e^{-cT^ζ}) for analytic quasi-periodic functions and with super-polynomial rates for Brjuno and almost-periodic cases.

  2. A corrective agentic hybrid RAG and an operations-grounded evaluation for a scientific facility

    physics.acc-ph 2026-07 conditional novelty 5.5 of 10

    A deployed hybrid RAG for APS operations improves vital-nugget recall over BM25 mainly via cross-encoder reranking; graph and corrective loops help only marginally on a 50-question facility benchmark.

  3. Lightweight CNN-Based Anomaly Detection for High Voltage Converter Modulators in the Spallation Neutron Source

    cs.LG 2026-05 unverdicted novelty 5.0 of 10

    On the public HVCM dataset, a factorized CNN that mixes 14 sensor channels before temporal filtering and re-weights them per pulse (PW-First+SE) beats joint-mixing and published baselines: pooled AUC-PR 0.816, AUC-ROC 0.934.

Pith tools