RECORD
Comparison of Radon Mass Exhalation Rate Measurements from Building Materials by two Different Methods
Medical Physics · Submitted 28 Jul 2020
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim Overall, the measured values for both methods present a good agreement.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
The aim of this study is to measure the radon mass exhalation rate from common granite building materials used in the East and Northeast part of Portugal. Twelve cubic shaped samples were measured. Nine of them without any coating and three coated with different materials (varnish,hydrorepellent and liquid silicone). The radon measurements were performed with two different techniques: one using passive detectors and other using an active detector. For the passive method CR-39 solid state nuclear track detectors were used. The active method used the RAD7 DURRIDGE detector. Radon mass exhalation rates obtained from both methods present relatively low values in the 11 to 45 mBq/kg/h range for the analyzed samples. Concerning the coated samples, the measured values are on average four times lower than the ones without coating. Overall, the measured values for both methods present a good agreement.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | The aim of this study is to measure the radon mass exhalation rate from common granite building materials used in the East and Northeast part of Portugal. | contribution 0.92 | 0.45 | 0.03 | asserted 0.91 |
| s1 | Twelve cubic shaped samples were measured. | method 0.99 | 0.92 | 0.02 | asserted 0.99 |
| s2 | Nine of them without any coating and three coated with different materials (varnish,hydrorepellent and liquid silicone). | method 0.99 | 0.87 | 0.02 | asserted 0.97 |
| s3 | The radon measurements were performed with two different techniques: one using passive detectors and other using an active detector. | method 0.99 | 0.92 | 0.03 | asserted 1.00 |
| s4 | For the passive method CR-39 solid state nuclear track detectors were used. | method 1.00 | 0.82 | 0.02 | asserted 1.00 |
| s5 | The active method used the RAD7 DURRIDGE detector. | method 1.00 | 0.81 | 0.02 | asserted 1.00 |
| s6 | Radon mass exhalation rates obtained from both methods present relatively low values in the 11 to 45 mBq/kg/h range for the analyzed samples. | result 1.00 | 0.96 | 0.19 | asserted 1.00 |
| s7 | Concerning the coated samples, the measured values are on average four times lower than the ones without coating. | result 1.00 | 0.96 | 0.25 | asserted 1.00 |
| s8 | Overall, the measured values for both methods present a good agreement. | result 0.67 | 0.94 | 0.55 | asserted 0.97 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
The aim of this study is to measure the radon mass exhalation rate from common granite building materials used in the East and Northeast part of Portugal. Twelve cubic shaped samples were measured. Nine of them without any coating and three coated with different materials (varnish,hydrorepellent and liquid silicone). The radon measurements were performed with two different techniques: one using passive detectors and other using an active detector. For the passive method CR-39 solid state nuclear track detectors were used. The active method used the RAD7 DURRIDGE detector. Radon mass exhalation rates obtained from both methods present relatively low values in the 11 to 45 mBq/kg/h range for the analyzed samples. Concerning the coated samples, the measured values are on average four times lower than the ones without coating. Overall, the measured values for both methods present a good agreement.
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.