Pith. sign in

REVIEW

Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2009.11227 v1 pith:K63NR73K submitted 2020-09-23 physics.ins-det physics.app-ph

Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

classification physics.ins-det physics.app-ph
keywords cmosactivityenergygammacameradetectableenergiesincident
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
abstract

This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $\gamma$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of x-rays and low energy $\gamma$-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2 %. The Neo sCMOS is not sensitive to x-rays with energies below $\sim\!\!10 keV$. The smallest detectable rate is 40$\pm$3 mHz, corresponding to an incident activity on the chip of 7$\pm$4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08$\pm$0.02 % (0.0011$\pm$0.0002 %) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4$\pm$1 mHz (1.5$\pm$0.1 mHz) for 26.3 keV (59.5 keV) $\gamma$-rays, which corresponds to an incident activity of 1.0$\pm$0.6 Bq (57$\pm$33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a $\gamma$- and x-ray detector with sensitivity at the few to 100 ppb level for Lead-210 in a sample.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.