Pith. sign in

REVIEW 1 cited by

Studying Robustness of Semantic Segmentation under Domain Shift in cardiac MRI

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2011.07592 v1 pith:5WAEHINO submitted 2020-11-15 eess.IV cs.CV

classification eess.IVcs.CV
keywords cardiacdomaindeepsegmentationautomaticdataimaginglearning
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Cardiac magnetic resonance imaging (cMRI) is an integral part of diagnosis in many heart related diseases. Recently, deep neural networks have demonstrated successful automatic segmentation, thus alleviating the burden of time-consuming manual contouring of cardiac structures. Moreover, frameworks such as nnU-Net provide entirely automatic model configuration to unseen datasets enabling out-of-the-box application even by non-experts. However, current studies commonly neglect the clinically realistic scenario, in which a trained network is applied to data from a different domain such as deviating scanners or imaging protocols. This potentially leads to unexpected performance drops of deep learning models in real life applications. In this work, we systematically study challenges and opportunities of domain transfer across images from multiple clinical centres and scanner vendors. In order to maintain out-of-the-box usability, we build upon a fixed U-Net architecture configured by the nnU-net framework to investigate various data augmentation techniques and batch normalization layers as an easy-to-customize pipeline component and provide general guidelines on how to improve domain generalizability abilities in existing deep learning methods. Our proposed method ranked first at the Multi-Centre, Multi-Vendor & Multi-Disease Cardiac Image Segmentation Challenge (M&Ms).

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Can Diffusion Models Bridge the Domain Gap in Cardiac MR Imaging?

    cs.CV 2025-08 reject novelty 4.0 of 10

    A source-domain diffusion model with reference-guided sampling is applied to cardiac MRI domain shift, with mixed evidence: surface metrics improve on synthetic test data but the domain-generalisation claim is contrad...

Pith tools