Pith. sign in

REVIEW 2 cited by

Bayesian noise wave calibration for 21-cm global experiments

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2011.14052 v4 pith:RBHVBALE submitted 2020-11-28 astro-ph.IM

classification astro-ph.IM
keywords calibrationbayesianexperimentslevelalgorithmdataglobalload
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Detection of millikelvin-level signals from the 'Cosmic Dawn' requires an unprecedented level of sensitivity and systematic calibration. We report the theory behind a novel calibration algorithm developed from the formalism introduced by the EDGES collaboration for use in 21-cm experiments. Improvements over previous approaches are provided through the incorporation of a Bayesian framework and machine learning techniques such as the use of Bayesian evidence to determine the level of frequency variation of calibration parameters that is supported by the data, the consideration of correlation between calibration parameters when determining their values and the use of a conjugate-prior based approach that results in a fast algorithm for application in the field. In self-consistency tests using empirical data models of varying complexity, our methodology is used to calibrate a 50 $\Omega$ ambient-temperature load. The RMS error between the calibration solution and the measured temperature of the load is 8 mK, well within the 1$\sigma$ noise level. Whilst the methods described here are more applicable to global 21-cm experiments, they can easily be adapted and applied to other applications, including telescopes such as HERA and the SKA.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Impact of numerical stability in Bayesian noise wave calibration on global 21-cm experiments

    astro-ph.CO 2026-07 conditional novelty 6.0 of 10

    Near-collinearity of noise-source and load design-matrix columns makes REACH’s five-parameter Bayesian calibration non-reproducible; a four-parameter Chebyshev fit with hot-load T_NS(ν) recovery and spike masking stab...

  2. Global 21cm Measurement Calibration Methodology

    astro-ph.CO 2026-07 accept novelty 5.0 of 10

    Three-way Dicke switching is inadequate for broadband global 21cm work; five independent calibrators plus the classical four noise parameters yield the correct absolute temperature, and Rogers & Bowman (2012) missed |...

Pith tools