RECORD
Characterization of a beam-tagging hodoscope for hadrontherapy monitoring
Instrumentation and Detectors · Submitted 6 Jan 2021
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim Overall, the performances show that such a technology is viable for beam monitoring during hadrontherapy.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber planes. The detection efficiency with a coincidence between the two planes is close to 75 % for beam intensities up to $\sim1$ MHz. Moreover, the timing resolution is around 1.8 ns FWHM. Overall, the performances show that such a technology is viable for beam monitoring during hadrontherapy.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. | method 0.76 | 0.93 | 0.03 | asserted 0.98 |
| s1 | This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber planes. | result 1.00 | 0.94 | 0.10 | asserted 1.00 |
| s2 | The detection efficiency with a coincidence between the two planes is close to 75 % for beam intensities up to $\sim1$ MHz. | result 1.00 | 0.95 | 0.05 | asserted 1.00 |
| s3 | Moreover, the timing resolution is around 1.8 ns FWHM. | result 1.00 | 0.91 | 0.03 | asserted 1.00 |
| s4 | Overall, the performances show that such a technology is viable for beam monitoring during hadrontherapy. | interpretation 1.00 | 0.60 | 0.95 | asserted 0.96 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber planes. The detection efficiency with a coincidence between the two planes is close to 75 % for beam intensities up to $\sim1$ MHz. Moreover, the timing resolution is around 1.8 ns FWHM. Overall, the performances show that such a technology is viable for beam monitoring during hadrontherapy.
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.