Pith. sign in

REVIEW 1 cited by

Bayesian modelling of multiple plasma diagnostics at Wendelstein 7-X

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2103.07582 v1 pith:5FORDYKG submitted 2021-03-13 physics.plasm-ph

classification physics.plasm-ph
keywords modeltemperaturedensityprofileselectronjointparametersposterior
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Consistent inference of the electron density and temperature has been carried out with multiple heterogeneous plasma diagnostic data sets at Wendelstein 7-X. The predictive models of the interferometer, Thomson scattering and helium beam emission spectroscopy systems have been developed in the Minerva framework and combined to a single joint model. The electron density and temperature profiles are modelled by Gaussian processes with their hyperparameters. The model parameters such as the calibration factor of the Thomson scattering system and the model predictive uncertainties are regarded as additional unknown parameters. The joint posterior probability distribution of the electron density and temperature profiles, hyperparameters of the Gaussian processes and model parameters is explored by Markov chain Monte Carlo algorithms. The posterior samples drawn from the joint posterior distribution are numerically marginalised over the hyperparameters and model parameters to obtain the marginal posterior distributions of the electron density and temperature profiles. The inference of these profiles is performed with different combinations of the interferometer and Thomson scattering data as well as either the empirical electron density and temperature constraints at the limiter/divertor positions introduced by \textit{virtual observations} or the edge density and temperature from the helium beam emission data. Furthermore, the addition of the X-ray imaging crystal spectrometers to the joint model for the ion temperature profiles is demonstrated. All these profiles presented in this work are inferred with the optimal hyperparameters and model parameters by exploring the full joint posterior distribution which intrinsically embodies Bayesian Occam's razor.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Integrated Data Analysis and Validation

    physics.plasm-ph 2024-11 accept novelty 3.0 of 10

    The paper reviews the Bayesian Integrated Data Analysis framework and shows a synthetic-data profile reconstruction prototype for three ITER diagnostics.

Pith tools