SPRINT: System Parameters Recurrent INvasive Tracking, a fast and least-cost online calibration strategy for adaptive optics

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2104.11261 v1 pith:7BS55VAY submitted 2021-04-22 astro-ph.IM

classification astro-ph.IM
keywords methodscientificwilladaptiveimpactmis-registrationsparameterssystem
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

The future large adaptive telescopes will trigger new constraints for the calibration of Adaptive Optics (AO) systems equipped with pre-focal Deformable Mirrors (DM). The image of the DM actuators grid as seen by the Wave-Front Sensor (WFS) may evolve during the operations due to the flexures of the opto-mechanical components present in the optical path. The latter will result in degraded AO performance that will impact the scientific operation. To overcome this challenge, it will be necessary to regularly monitor and compensate for these DM/WFS mis-registrations either by physically re-aligning some optical components or by updating the control matrix of the system. In this paper, we present a new strategy to track mis-registrations using a pseudo-synthetic model of the AO system. The method is based on an invasive approach where signals are acquired on-sky, before or during the scientific operations, and fed to the model to extract the mis-registration parameters. We introduce a method to compute the most sensitive modes to these mis-registrations that allows to reduce the number of degrees of freedom required by the algorithm and minimize the impact on the scientific performance. We demonstrate that, using only a few of these well selected signals, the method provides a very good accuracy on the parameters estimation, well under the targeted accuracy, and has a negligible impact on the scientific path. In addition, the method appears to be very robust to varying operating conditions of noise and atmospheric turbulence and performs equally for both Pyramid and Shack-Hartmann WFS.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. High strehl and high contrast for the ELT instrument METIS -- Final design, implementation, and predicted performance of the single-conjugate adaptive optics system

    astro-ph.IM 2024-11 conditional novelty 5.0 of 10

    The METIS SCAO final design is predicted to meet its Strehl and contrast requirements in end-to-end simulations, with robustness to combined error sources.